== Fault-finding ==
 
== Fault-finding ==
 
* No CH or DHW
 
* No CH or DHW
 +
** boiler working? - boiler fault-finding guide (Ed?)
 +
 
* No CH, DHW OK
 
* No CH, DHW OK
 
** conventional
 
** conventional
 +
*** programmer, room stat or zone valve prob
 
** combi
 
** combi
 +
*** programmer or room stat, (diverter stucK?)
 
* CH OK, no DHW
 
* CH OK, no DHW
 
** conventional
 
** conventional
 +
*** programmer, cylinder stat or zone valve prob
 
** combi
 
** combi
 +
*** diverter valve if PHE design, flow switch or scaling if combined heat exchanger
 +
 
* DHW OK, some parts of CH not working
 
* DHW OK, some parts of CH not working
 
** rad(s) compeletely cold
 
** rad(s) compeletely cold
*** balancing
+
*** balancing - try turning off other rads
*** stuck TRV
+
*** stuck TRV - take head off pull up pin (carefully - can pull out and leak on some)
*** completely full of air
+
*** completely full of air - bleed & find cause
 
** rad(s) lukewarm
 
** rad(s) lukewarm
 
*** balancing
 
*** balancing
Line 30: Line 37:
 
** rad(s) cold at bottom
 
** rad(s) cold at bottom
 
*** sludge
 
*** sludge
 +
* CH on when should be off
 +
** All rads on
 +
*** timer? room stat? zone valve?
 +
** Some rads on
 +
*** reverse circulation
 +
*** rad on DHW circuit - often in bathroom: may be design "feature"
  
 
=== rads constantly need bleeding ===
 
=== rads constantly need bleeding ===

Revision as of 18:40, 15 February 2007

This article is about Central Heating systems using hot water as a heat-carrying medium. (Warm-air systems are sometimes found in the UK but their design and installation is not covered here. There is a discussion on updating existing warm-air systems here)

The article is about diagnosing and fixing a faulty central heating system.

There are separate articles about:

This article is a skeleton: the main points to be covered are listed but some or all still need to be expanded

Fault-finding

  • No CH or DHW
    • boiler working? - boiler fault-finding guide (Ed?)
  • No CH, DHW OK
    • conventional
      • programmer, room stat or zone valve prob
    • combi
      • programmer or room stat, (diverter stucK?)
  • CH OK, no DHW
    • conventional
      • programmer, cylinder stat or zone valve prob
    • combi
      • diverter valve if PHE design, flow switch or scaling if combined heat exchanger
  • DHW OK, some parts of CH not working
    • rad(s) compeletely cold
      • balancing - try turning off other rads
      • stuck TRV - take head off pull up pin (carefully - can pull out and leak on some)
      • completely full of air - bleed & find cause
    • rad(s) lukewarm
      • balancing
      • faulty TRV
    • rad(s) cold at top
      • bleeding
    • rad(s) cold at bottom
      • sludge
  • CH on when should be off
    • All rads on
      • timer? room stat? zone valve?
    • Some rads on
      • reverse circulation
      • rad on DHW circuit - often in bathroom: may be design "feature"

rads constantly need bleeding

  • air or hydrogen in system? (lighter test - with care!)
    • corrosion:
      • inhibitor?
      • vented system? - pumping over?
    • air
      • pinhole leaks?
      • vented system? - pumping over?