Central Heating Repair

From DIYWiki
Revision as of 19:12, 15 February 2007 by John Stumbles (talk | contribs) (add sections)
Jump to navigation Jump to search

This article is about Central Heating systems using hot water as a heat-carrying medium. (Warm-air systems are sometimes found in the UK but their design and installation is not covered here. There is a discussion on updating existing warm-air systems here)

The article is about diagnosing and fixing a faulty central heating system.

There are separate articles about:

This article is a skeleton: the main points to be covered are listed but some or all still need to be expanded

Fault-finding

  • No CH or DHW
    • boiler working? - boiler fault-finding guide (Ed?)
    • sealed system? - pressure OK?
  • No CH, DHW OK
    • conventional
      • programmer, room stat or zone valve prob
    • combi
      • programmer or room stat, (diverter stucK?)
  • CH OK, no DHW
    • conventional
      • programmer, cylinder stat or zone valve prob
    • combi
      • diverter valve if PHE design, flow switch or scaling if combined heat exchanger
  • DHW OK, some parts of CH not working
    • rad(s) compeletely cold
      • balancing - try turning off other rads
      • stuck TRV - take head off pull up pin (carefully - can pull out and leak on some)
      • completely full of air - bleed & find cause
      • only upstairs working? pump failed?
      • only downstairs working? vented system? loss of water?
    • rad(s) lukewarm
      • balancing
      • faulty TRV
    • rad(s) cold at top
      • bleeding
    • rad(s) cold at bottom
      • sludge
  • CH on when should be off
    • All rads on
      • timer? room stat? zone valve?
    • Some rads on
      • reverse circulation
      • rad on DHW circuit - often in bathroom: may be design "feature"

rads constantly need bleeding

  • air or hydrogen in system? (lighter test - with care!)
    • corrosion:
      • inhibitor?
      • vented system? - pumping over? - check feed & expansion connections (<150mm apart), header tank level, vent pipe rise & termination height, pump speed setting (old system pump replaced with newer model?)
    • air
      • pinhole leaks?
      • vented system? - pumping over?

noises

  • screeching from pump: vented? loss of water? float valve stuck or feed pipe blocked - sludge or scale
  • kettling from boiler: scale - X200 etc
  • clicking, knocking from floors & walls: pipework expanding & contracting - expose and free up