Central Heating Repair

From DIYWiki
Revision as of 14:58, 20 February 2007 by John Stumbles (talk | contribs) (formatting)
Jump to navigation Jump to search

This article is about Central Heating systems using hot water as a heat-carrying medium. (Warm-air systems are sometimes found in the UK but their design and installation is not covered here. There is a discussion on updating existing warm-air systems here)

The article is about diagnosing and fixing a faulty central heating system.

There are separate articles about:

This article is a skeleton: the main points to be covered are listed but some or all still need to be expanded

Fault-finding

No CH or DHW

All systems
boiler working? - boiler fault-finding guide (Ed?)
sealed system
pressure OK?

No CH, DHW OK

conventional system
programmer, room stat or zone valve prob
combi boiler
programmer or room stat, (diverter stucK?)

CH OK, no DHW

conventional system
programmer, cylinder stat or zone valve prob
combi boiler with PHE & diverter valve
diverter valve
combi boiler with combined heat exchanger
flow switch or scaling

DHW OK, some parts of CH not working

some rad(s) compeletely cold
  • balancing - try turning off other rads
  • stuck TRV - take head off pull up pin (carefully - can pull out and leak on some)
  • completely full of air - bleed & find cause
  • only upstairs working? pump failed?
  • only downstairs working? vented system? loss of water?
some rad(s) lukewarm
  • balancing
  • faulty TRV
rad(s) cold at top
bleeding
rad(s) cold at bottom
sludge

CH on when should be off

All rads on
  • timer?
  • room stat?
  • zone valve?
Some rads on
reverse circulation
rad on DHW circuit - often in bathroom: may be design "feature"

rads constantly need bleeding

  • air or hydrogen in system? (lighter test - with care!)
    • corrosion:
      • inhibitor?
      • vented system? - pumping over? - check feed & expansion connections (<150mm apart), header tank level, vent pipe rise & termination height, pump speed setting (old system pump replaced with newer model?)
    • air
      • pinhole leaks?
      • vented system? - pumping over?

system pressure dropping

This applies to sealed systems only.

Possible causes (see also Ed's Sealed System FAQ)

  • leaking Pressure Relief Discharge (PRD) Valve
  • problem with expansion vessel:
    • lack of air/gas pressure in vessel
    • ruptured diaphragm
  • leak in pipework

See discussion on uk.d-i-y on Tracing tiny leaks in sealed system

noises

  • screeching from pump: vented? loss of water? float valve stuck or feed pipe blocked - sludge or scale
  • kettling from boiler: scale - X200 etc
  • clicking, knocking from floors & walls: pipework expanding & contracting - expose and free up
  • rushing noises from pipes and radiators - air in system?