Difference between revisions of "Dating Old Electrics"

From DIYWiki
Jump to navigation Jump to search
(write article)
(linkify)
Line 4: Line 4:
 
Some dates - but may contain errors, and sometimes things did get installed later than they should strictly have been.
 
Some dates - but may contain errors, and sometimes things did get installed later than they should strictly have been.
  
Cables:
+
[[Cable]]s:
 
*Lead sheath cable: before 1948, except on farms
 
*Lead sheath cable: before 1948, except on farms
 
*TRS (Tough Rubber Sheath) 1945-1962
 
*TRS (Tough Rubber Sheath) 1945-1962
 
*Capothene and Ashothene sheath cables: 1952 - 1960
 
*Capothene and Ashothene sheath cables: 1952 - 1960
*PVC inner PVC outer T&E style cables with no cpc (lighting circuits): 1955-1966
+
*PVC inner PVC outer [[Cable|T&E]] style cables with no cpc ([[House Wiring for Beginners|lighting circuits]]): 1955-1966
 
*Imperial PVC cables: 1955 - 1971
 
*Imperial PVC cables: 1955 - 1971
 
*2.5mm PVC/PVC T&E with 1mm cpc: 1971 - 1981
 
*2.5mm PVC/PVC T&E with 1mm cpc: 1971 - 1981
*Twin twisted flexible cords: before 1977
+
*Twin twisted [[flex]]ible cords: before 1977
 
*Rubber/PVC mix T&E cable: 1958 to 1961  
 
*Rubber/PVC mix T&E cable: 1958 to 1961  
  
Line 20: Line 20:
 
*Green & yellow earth sleeving: 1971 onwards
 
*Green & yellow earth sleeving: 1971 onwards
  
Main earth bonding:
+
Main [[Earthing and Bonding|earth bonding]]:
 
*No main equiptential bonding conductor: before 1966
 
*No main equiptential bonding conductor: before 1966
 
*2.5mm main equipotential bonding conductors: 1971-1972
 
*2.5mm main equipotential bonding conductors: 1971-1972
Line 26: Line 26:
 
*10mm main equipotential bonding conductors: post 1983
 
*10mm main equipotential bonding conductors: post 1983
  
Fuseboards:
+
[[Fusebox|Fuseboards]]:
*ELCB (Voltage operated circuit breaker): pre 1981
+
*[[RCD|ELCB]] (Voltage operated circuit breaker): pre 1981
*Double pole fused switchgear on ac Installations: pre 1955
+
*Double pole [[fuse]]d switchgear on ac Installations: pre 1955
*Wood backed Wylex fuseboxes: still being installed in 1983
+
*Wood backed Wylex [[fusebox]]es: still being installed in 1983
*Slate fusebox with bare screws for fusewire links: in use in late 1800s, obsolete by the 1930s
+
*Slate fusebox with bare [[screw]]s for fusewire links: in use in late 1800s, obsolete by the 1930s
 
*Wooden box with wooden lid fusebox: standard in 1930s
 
*Wooden box with wooden lid fusebox: standard in 1930s
  

Revision as of 22:35, 3 November 2010

300px


Some dates - but may contain errors, and sometimes things did get installed later than they should strictly have been.

Cables:

  • Lead sheath cable: before 1948, except on farms
  • TRS (Tough Rubber Sheath) 1945-1962
  • Capothene and Ashothene sheath cables: 1952 - 1960
  • PVC inner PVC outer T&E style cables with no cpc (lighting circuits): 1955-1966
  • Imperial PVC cables: 1955 - 1971
  • 2.5mm PVC/PVC T&E with 1mm cpc: 1971 - 1981
  • Twin twisted flexible cords: before 1977
  • Rubber/PVC mix T&E cable: 1958 to 1961

Earth wire in cables:

  • Separate bare copper earth wires run alongside twin cable:
  • Black earth conductors: before 1966
  • Green protective sleeving: before 1977
  • Green & yellow earth sleeving: 1971 onwards

Main earth bonding:

  • No main equiptential bonding conductor: before 1966
  • 2.5mm main equipotential bonding conductors: 1971-1972
  • 6mm main equipotential bonding conductors: 1966 - 1983
  • 10mm main equipotential bonding conductors: post 1983

Fuseboards:

  • ELCB (Voltage operated circuit breaker): pre 1981
  • Double pole fused switchgear on ac Installations: pre 1955
  • Wood backed Wylex fuseboxes: still being installed in 1983
  • Slate fusebox with bare screws for fusewire links: in use in late 1800s, obsolete by the 1930s
  • Wooden box with wooden lid fusebox: standard in 1930s

Sockets:

  • Accessories mounted on wooden blocks: before 1966
  • Round pin socket outlets: mostly before 1955, but sometimes used much later
  • Square pin 13A sockets: post 1945
  • 2 pin 5A sockets:
  • No sockets upstairs:


See Also