Dating Old Electrics

From DIYWiki
Revision as of 22:35, 3 November 2010 by NT (talk | contribs) (linkify)
Jump to navigation Jump to search

300px


Some dates - but may contain errors, and sometimes things did get installed later than they should strictly have been.

Cables:

  • Lead sheath cable: before 1948, except on farms
  • TRS (Tough Rubber Sheath) 1945-1962
  • Capothene and Ashothene sheath cables: 1952 - 1960
  • PVC inner PVC outer T&E style cables with no cpc (lighting circuits): 1955-1966
  • Imperial PVC cables: 1955 - 1971
  • 2.5mm PVC/PVC T&E with 1mm cpc: 1971 - 1981
  • Twin twisted flexible cords: before 1977
  • Rubber/PVC mix T&E cable: 1958 to 1961

Earth wire in cables:

  • Separate bare copper earth wires run alongside twin cable:
  • Black earth conductors: before 1966
  • Green protective sleeving: before 1977
  • Green & yellow earth sleeving: 1971 onwards

Main earth bonding:

  • No main equiptential bonding conductor: before 1966
  • 2.5mm main equipotential bonding conductors: 1971-1972
  • 6mm main equipotential bonding conductors: 1966 - 1983
  • 10mm main equipotential bonding conductors: post 1983

Fuseboards:

  • ELCB (Voltage operated circuit breaker): pre 1981
  • Double pole fused switchgear on ac Installations: pre 1955
  • Wood backed Wylex fuseboxes: still being installed in 1983
  • Slate fusebox with bare screws for fusewire links: in use in late 1800s, obsolete by the 1930s
  • Wooden box with wooden lid fusebox: standard in 1930s

Sockets:

  • Accessories mounted on wooden blocks: before 1966
  • Round pin socket outlets: mostly before 1955, but sometimes used much later
  • Square pin 13A sockets: post 1945
  • 2 pin 5A sockets:
  • No sockets upstairs:


See Also