'''Neon [[screwdrivers]]''' are used to test mains circuits to see if they're live. However they have significant problems, and the majority view on [[Newsgroup access tips|uk.d-i-y]] is they're best not used at all.
+
'''Neon [[screwdrivers]]''' are fairly crude tools that combine the functions of a small terminal screwdriver with a [[Electricity Basics|mains voltage]] detector. However they have a number of safety problems, and the majority view on [[Newsgroup access tips|uk.d-i-y]] is that the voltage detection capability is best not used at all.
  
  
 
==How they work==
 
==How they work==
Mains power flows down the screw driving tip to the resistor and neon in the handle. When you touch the brass cap, mains power flows through you, completing the [[House Wiring for Beginners|circuit]] and lighting the neon.
+
Mains power flows down the screw driving tip to the resistor and [[Lighting|neon]] in the handle. When you touch the brass cap, the body's natural capacitance allows enough power to flow through the screwdriver and the user to cause the neon to light.
  
The currents involved are small enough not to feel, so the normal current level is not a safety concern.
+
This small current is entirely harmless, there is no electric shock under normal circumstances.
  
  
 
==The Problems==
 
==The Problems==
 
===Direct shock===
 
===Direct shock===
[[Water]] or condensation on the resistor can result in the tool passing higher current to the user, causing a shock, maybe a fall from a ladder, and the slight risk of fatality.
+
[[Water]] or condensation on the resistor can result in the [[tool]] shocking the user, maybe causing a fall from a [[ladder]]. Hence never hold one of these screwdrivers in your mouth, eg when working with both hands.  
 
 
Certain tool faults such as resistor failure can cause the same problem.
 
  
 +
Certain [[Tools|tool]] faults such as resistor a failure can create similar risks.
  
 
===False negative===
 
===False negative===
The [[lighting]] of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live [[cables|wire]], and this is probably the most common failure mechanism.
+
The [[lighting]] of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live [[cables|wire]], and this is probably the most common failure mode.
  
Not being connected to or near earth, eg up a wooden ladder, can reduce current flow further, reducing light output and making the dimness situation worse.
+
Not being connected to or near [[earth]], insulated from ground, can reduce current flow further, making the neon even dimmer. The body being capacitively coupled to some other nearby [[Cable|live conductor]], can prevent the light [[lighting]] at all, even when the screw driver tip is touching a live wire or contact.  
  
 
===False Positive===
 
===False Positive===
A user capacitively connected to a live supply will light a neon screwdriver touched to any non-live [[cables|wire]]. It is quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a cable, even leaning on a wall in some cases, and so on.
+
A user capacitively connected to a live supply will light a neon screwdriver touched to a non-live [[cables|wire]]. Its quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a [[cable]], even leaning on a [[wall]] in some cases, and so on. Also touching a "floating" conductor (i.e. an unconnected wire that is routed in close proximity to other live wires) may also yield a false positive test.
 +
 
 +
==Minimising risk / safe use==
 +
If you must use one of these devices, then adopt a sound "proven dead" approach to testing. Before making a test, test the screwdriver on a known live conductor and ensure it lights up. Next test the unknown conductor, and ensure it does not light, Finally test again on a known live conductor.  
  
 +
Avoid putting the tool anywhere that may expose it to allow [[water]] or [[Damp|condensation]], such as a [[shed]], outdoors, in one's mouth etc.
  
 
===Legality===
 
===Legality===
Because of the issues with these [[Hand Tools|tools]], they are illegal to use at a place of work.
+
There is some question as to whether these [[Hand Tools|tools]], are legal to use in the workplace, since they don't possess a number of the attributes deemed necessary in electrical test gear by the health and safety executive. See the document GS38 [http://www.hse.gov.uk/pubns/priced/gs38.pdf Electrical Test Equipment for Electricians] (PDF) - in particular section 9.
 
 
  
 
==Further discussion==
 
==Further discussion==
 
[http://groups.google.co.uk/group/uk.d-i-y/browse_frm/thread/007f918ced3f909c?hl=en# uk.d-i-y thread]
 
[http://groups.google.co.uk/group/uk.d-i-y/browse_frm/thread/007f918ced3f909c?hl=en# uk.d-i-y thread]
  
 +
==Alternatives==
 +
One alternative is a non-contact volt stick:
  
==Alternatives==
+
[[image:VoltStick-2.jpg]]
Better alternatives include a non contact volt stick, or a [[multimeter]]. A reasonable quality meter will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are less and much more under the control of the end user, so can be minimised with care.
+
 
 +
These remove the direct shock risk but suffer false negatives and false positives, so can fail to indicate a live circuit. They are useful as they're fast, since no conducor need be bared to take a reading. But relying on them before touching a potentially live wire is not recommended, and not legal in a work setting.
 +
 
 +
A [[multimeter]] or voltmeter can will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are much less and more under the control of the end user, so can be minimised with care.
  
 
==See Also==
 
==See Also==
Line 45: Line 52:
 
[[Category:Electrical]]
 
[[Category:Electrical]]
 
[[Category:Safety]]
 
[[Category:Safety]]
 +
[[Category:Tools]]

Latest revision as of 23:19, 3 December 2017

Phasenpruefer 01-l KMJ.jpg

Neon screwdrivers are fairly crude tools that combine the functions of a small terminal screwdriver with a mains voltage detector. However they have a number of safety problems, and the majority view on uk.d-i-y is that the voltage detection capability is best not used at all.


How they work

Mains power flows down the screw driving tip to the resistor and neon in the handle. When you touch the brass cap, the body's natural capacitance allows enough power to flow through the screwdriver and the user to cause the neon to light.

This small current is entirely harmless, there is no electric shock under normal circumstances.


The Problems

Direct shock

Water or condensation on the resistor can result in the tool shocking the user, maybe causing a fall from a ladder. Hence never hold one of these screwdrivers in your mouth, eg when working with both hands.

Certain tool faults such as resistor a failure can create similar risks.

False negative

The lighting of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live wire, and this is probably the most common failure mode.

Not being connected to or near earth, insulated from ground, can reduce current flow further, making the neon even dimmer. The body being capacitively coupled to some other nearby live conductor, can prevent the light lighting at all, even when the screw driver tip is touching a live wire or contact.

False Positive

A user capacitively connected to a live supply will light a neon screwdriver touched to a non-live wire. Its quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a cable, even leaning on a wall in some cases, and so on. Also touching a "floating" conductor (i.e. an unconnected wire that is routed in close proximity to other live wires) may also yield a false positive test.

Minimising risk / safe use

If you must use one of these devices, then adopt a sound "proven dead" approach to testing. Before making a test, test the screwdriver on a known live conductor and ensure it lights up. Next test the unknown conductor, and ensure it does not light, Finally test again on a known live conductor.

Avoid putting the tool anywhere that may expose it to allow water or condensation, such as a shed, outdoors, in one's mouth etc.

Legality

There is some question as to whether these tools, are legal to use in the workplace, since they don't possess a number of the attributes deemed necessary in electrical test gear by the health and safety executive. See the document GS38 Electrical Test Equipment for Electricians (PDF) - in particular section 9.

Further discussion

uk.d-i-y thread

Alternatives

One alternative is a non-contact volt stick:

VoltStick-2.jpg

These remove the direct shock risk but suffer false negatives and false positives, so can fail to indicate a live circuit. They are useful as they're fast, since no conducor need be bared to take a reading. But relying on them before touching a potentially live wire is not recommended, and not legal in a work setting.

A multimeter or voltmeter can will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are much less and more under the control of the end user, so can be minimised with care.

See Also