'''Lots of useful information for anyone about to rewire.'''
+
'''Lots of useful information for anyone due to rewire.'''
  
 +
This article collects together some of the options and suggestions for improving the functionality of any new wiring system. It does not include details of the mechanics of installing wiring. For that please see the [[Electrical_Installation|Electrical Installation]] article.
  
==Introduction==
+
 
The basic electrical installation design is fairly much decided by the 16th edition wiring regs, so unless you get into specialist, unusual or illegal territory, most of the choices are already made for you.
+
=The Basics=
 +
The basic electrical installation design is fairly much decided by the [[Regulations|17th edition wiring regs]] which came into force on 1 July 2008 , so unless you get into specialist, unusual or illegal territory, many of the choices are already made for you.
  
 
You're still left with quite a lot of details to choose from. These details can affect comfort, safety, reliability, and avoid unnecessary trouble and expense. In sum these many details can make quite a difference. A lot of good choices can be made at little or no cost, and several will save money.
 
You're still left with quite a lot of details to choose from. These details can affect comfort, safety, reliability, and avoid unnecessary trouble and expense. In sum these many details can make quite a difference. A lot of good choices can be made at little or no cost, and several will save money.
Line 9: Line 11:
  
 
==The Basic System==
 
==The Basic System==
You'll get 30A rings supplying the sockets, or occasionally 20A radials. You'll get 6A lighting circuits, or occasionally 10A. Youll get dedicated feed for cooker and shower if you've got those, or the oven might end up on a 13A plug these days. You'll usually get 1 or 2 RCDs, which in a minority of cases can produce endless frustration by taking out the power on a frequent basis.
+
You'll get 32A ring circuits supplying the sockets, or occasionally 20A radials. You'll get 6A lighting circuits, or occasionally 10A. You'll get dedicated feeds for cooker and shower if you've got those, or the oven might end up on a 13A plug.  
 +
 
 +
You'll normally get at least 1 [[RCD]], which in a small minority of cases can produce a lot of frustration by frequently taking out the power (see [[RCD#Nuisance_trips|nuisance trips]]).
 +
 
 +
 
 +
=Glossary=
 +
'''[[CU]]''': consumer unit, the modern version of a fusebox.
 +
 
 +
'''[[CU|Split load CU]]''': A CU divided into at least 2 sections, each with its own main switch or [[RCD]]. A good idea. It means power can stay on no matter what happens to one section of the wiring. Even during a partial rewire sections of the power can stay on.
 +
 
 +
'''[[MCB]]''': a pushbutton overcurrent trip found in the consumer unit. This replaces a [[fuse]]. Although now unpopular, [[Fuse|Rewirable fuses]] are still fully compliant with today's wiring regs. Contrary to popular myth, [[MCB]]s are not a significant [[MCB#Comparison with Fuses|safety benefit]] for general use, but they are easier to reset. Where they are a safety plus is when householders can be expected to be irresponsible, eg rented property. [[MCB]]s should be chosen in these cases, as [[Fuse|rewirable fuse]]s are easy to abuse.
 +
 
 +
'''[[RCD]]''': earth leakage trip found in the consumer unit. This will trip if earth leakage current is too high, and reduces the risk of electrocution. Unfortunately they're known for nuisance trips, especially when configured with a single device protecting all the circuits (a so called "whole house" RCD). The majority of old installs have no [[RCD]].
 +
 
 +
'''[[Earthing Types|TT]]''': a type of earthing that uses a local earth rod. [[Earthing Types|TT]] installations require all circuits to be RCD protected since an [[Earthing Types|earth rod]] alone is usually inadequate to clear earth faults.
 +
 
 +
=The Choices=
 +
Now some ideal choices. Many will add a bit to installation cost, but are well worth it. Many cost nothing extra, and a few cost a lot. One can make many good choices without adding a lot to the cost.
 +
 
 +
 
 +
=Split Load CU=
 +
Use of a split load CU means one some of your wiring can be turned off while the rest stays on. So whatever may happen with your electrical system*, you don't need to turn it all off. This enables you to have power in the event of a fault, and to have power while working on the installation itself.
 +
Split load CUs are common today (especially with wiring compliant with the 17th edition of the wiring regs)
 +
Typical extra cost: £0
 +
 
 +
<nowiki>*</nowiki>there are exceptions of course, such as lightning strike or a major fire.
 +
 
 +
 
 +
=RCDs=
 +
[[RCD]]s are almost universal in new installs. See the [[RCD#System_design_using_RCDs|RCD System Notes]] article for details of how to design a system to make best use of these.
 +
 
 +
What you don't want is the deprecated install of one [[RCD]] supplying half or even the whole house. While many of these work OK, some create no end of frustration, trouble and expense for the householder. For £35-£100 more you can have 2 or 3 [[RCD#Types_of_RCD|RCBOs]] instead of one [[RCD]], which eliminates many [[RCD]] nuisance trips, and minimises the consequences of any that do occur. This way if an RCD trips, you lose power to one socket circuit instead of all power.
 +
 
 +
Historically, (unless you had a [[Earthing Types|TT earthing system]]), [[lighting]] would usually not be on an [[RCD]]. [[Lighting]] circuits have not proven to be a significant electrocution risk in themselves. The cable protection requirements of the 17th edition (not to mention the bathroom electrics one) will tend to mean that lighting circuits are now protected by RCDs. Hence its wise to design your system to mitigate any risks of unexpected loss of lighting that could result.
 +
 
 +
=Dedicated Freezer Feed=
 +
A freezer is best put on its own dedicated feed installed in non [[RCD]] protected way of the [[CU|consumer unit]], so other appliance faults don't stop it working and ruin £££ of food and days of your cooking efforts, or risk food poisoning.
  
 +
The risks of food poisoning from poor storage far outweigh those of shock from freezers, so no [[RCD]] on the freezer supply is the safer option.
 +
# To meet [[Regulations|16th edn regs]], this means the socket for the freezer should not be likely to be used by outdoor tools, so don't put the socket by the back door.
 +
# The [[Regulations|17th edition]], does not preclude a non-RCD socket for fridge/freezers provided the cable installation
 +
*is either surface mounted or follows the rules a-d listed here [[ Cable_Routes_and_Protection|Cables in a wall or partition
 +
]]
 +
*and the socket is clearly labelled for fridge/freezer use only.
  
==Glossary==
 
  
'''CU''': consumer unit, the modern version of a fusebox.
+
The next best option is to use a feed from a dedicated [[RCD|RCBO]] on a non [[RCD]] protected section of the consumer unit. This may still trip due to earth leakage caused by a faulty fridge or a damaged cable, but won't be tripped by faults on other circuits.
  
'''Split load CU''': A CU divided into 2 halves, each with its own main switch. A good idea. It means power can stay on no matter what happens to one section of the wiring. Even during a partial rewire half the power can stay on.
+
=Sockets=
 +
[[image:13A_double_socket.jpg|right|185px]]
 +
You need enough. Double sockets are not adequate by themselves to run the amount of electronics we use today (the last socket I put in was a 12 way). On the other hand, installing large numbers of fixed sockets is an eyesore and expensive. Doubles are enough if you sprinkle them around the room, and don't mind using several 4 & 6 way extension leads.
  
'''MCB''': a pushbutton overcurrent trip found in the consumer unit. This replaces a fuse. Rewirable fuses are still fully compliant with today's wiring regs. Contrary to popular myth, MCBs are not a significant safety benefit for general use, but they are easier to reset. Where householders can be expected to be irresponsible, eg rented property, mcbs should be chosen, as rewirable fuses are easy to abuse.
+
If the cable for the socket circuit is run round most of the room at socket height, its relatively easy to add more sockets in future wherever you need them.
  
'''RCD''': earth leakage trip found in the consumer unit, aka fusebox. This will trip if earth leakage current is too high, and reduce the risk of electrocution. Unfortunately they're well known for nuisance trips. The majority of older installs have no RCD.
+
=Halogen Lighting=
 +
[[image:Halogen_lamp_macro_4.jpg|thumb|Halogen reflector lamp]]
 +
[[image:Halogen_lamp_operating 3.jpg|thumb|Halogen capsule lamp]]
  
'''TT''': a type of earthing that uses a local earth rod. TT installs must have a whole house 100mA delayed RCD, since an earth rod alone is inadequate to clear faults. Whole house RCDs should be avoided with other installation types, as they're a known source of problems.
+
[[Halogen Lighting|Halogen downlighters]] are popular today, but have some downsides. They're expensive to run, are one of the most [[Save Energy & Money|energy inefficient]] options available, heat the house up in summer, they make lying right back in your own home truly uncomfortable, and they tend to give uneven illumination and glare. [[Halogen Lighting|Halogen lights]] are also the type most capable of starting fires, and most [[Halogen Lighting|halogen downlighters]] pierce the ceiling plasterboard fire and smoke barrier. There are approx 69,000 house fires per year in the UK.
  
 +
Its a good idea to calculate run costs before installing halogen, to avoid regret. As an example, 500w of halogen downlighters on 6 hours a day would cost £65 per year per room in electricity, plus 12-24 bulb replacements per year at £1 each, making a total cost of £77 per room per year. 4 rooms of this would equal £308 per year, or £9000 per 30 year product life*. For comparison, a similar level of [[CFL]] lighting would cost around £2000. (The exact amount will depend how much you install.) For some people that cost is fine, but for some its not the best way to spend the money.
  
==The Choices==
+
For those that want the look of [[Halogen Lighting|halogen]] without the energy use, there is the option to use lower power [[Halogen Lighting|halogen downlighters]], eg 5w, 10w or 20w, making up the rest of the light level with more efficient light sources, such as [[Uplighters|uplighting]] or concealed [[lighting]].
Now some ideal choices. Many will add a bit to installation cost, but are well worth it. Many cost nothing extra, and a few cost a lot. One can make many good choices for as little as an extra £100 in total.
 
  
 +
Below 150w, mains voltage [[Halogen Lighting|halogens]] are less efficient and less reliable than 12v halogen. Mains bulbs are lower efficiency compared to low voltage ones, more fragile, shorter lived, and more susceptible to early failures. They're also more cost per bulb. Low voltage does cost slightly more to install, but the extra cost is repaid many times over in use.
  
==Split Load CU:==
+
<nowiki>*</nowiki> Its actually more complex than that, and needs to be calculated for each case. The figure given just gives some idea of what those new [[Halogen Lighting|halogen fittings]] will really cost.
Use of a split load CU means one half of your wiring can be turned off while the other half stays on. So whatever may happen with your electrical system*, you dont need to turn it all off. This enables you to have power in the event of a fault, and to have power while working on the installation itself.
+
 
Split load CUs are common today, just check you get one.
+
=Switchbanks=
Typical extra cost: £0
+
[[image:Switchbank new 1083-6.jpg|thumb|Switchbank]]
 +
 
 +
Fitting [[Dimmers & Switchbanks|switchbanks]] where possible improves comfort and reduces electricity bills a little. These are 2 or more switches in the one box, where one would traditionally find a single switch. Each switch controls some of the [[lighting]]. Thus it is easy to control [[lighting]] brightness. Cost is about £1 more per switch point, and they typically save this much in under a year.
 +
 
 +
The easy ability to adjust brightness significantly improves both living comfort and utility, [[Save Energy & Money|saves energy]], and reduces cost of energy and hassle of [[Lamp Life|replacement bulbs]].
 +
 
 +
Using [[Dimmers & Switchbanks|dimmers]] to achieve a similar result results in much greater electricity use, as bulb efficiency falls very rapidly with dimming. It may also cause practical problems if filament bulbs are banned, which looks fairly likely, as dimmers are incompatible with most other lamp types.
 +
 
 +
=Uplighters=
 +
[[image:Uplighter 0996-2.jpg|thumb|R80 Uplighter]]
  
*there are exceptions, such as lightning strike
+
[[Uplighters|Uplighting]] uses the ceiling as a large diffuse source of light for the room. This gives less shadows and dark spots and more even illumination, than other lighting types, and better energy efficiency than downlighting. With white ceilings of at least normal height, uplighting is a good approach to general lighting.
  
 +
For [[Uplighters|uplighting]], spotlight fittings with ordinary GLS bulbs or [[CFL]]s in (not spotlight bulbs) are effective, look good, work well, and minimise bulb cost. Such fittings need to shroud the bulb. For large uplighters, PAR38 spotlight fittings that wrap around the bulb work well, again using GLS or [[CFL]] bulbs, not PARs.
  
==RCDs==
+
Plaster [[uplighters]] are not recommended, really they're inappropriate for [[Uplighters|uplighting]]. They create a high intensity light patch on the wall, which [[Uplighters|uplighting]] is intended to avoid. They light the wall from such a shallow angle as to magnify and illuminate even the tiniest blemish, making the wall look a mess.
RCDs are almost universal in new installs. Unfortunately theyre also a source of a good deal of trouble for a minority of householders.
 
  
What you don't want is the default install of one 30mA RCD covering half or even the whole house. Most of these work ok, but some create no end of frustration, trouble and expense for the householder. For £35-£100 more you can have 2 or 3 RCBOs instead of one RCD, which eliminates many RCD nuisance trips, and minimises the consequences of any that do occur. This way if an RCBO trips, you lose only one socket circuit instead of all power.
+
Halogen [[uplighters]] are a particular risk, they quickly ignite any paper or plastic that lands on them, or that they land on, and there are already too many deaths in house fires.
  
Unless you have a TT earthing system, lighting should not be on an RCD*. Lighting circuits have not proven to be a significant electrocution risk. RCDs tend to cause lighting to fail early in a fire, and this has resulted in the death of people failing to escape. Lighting is not usually on RCD**, but many such setups are in use.
+
=Kitchen worktop lighting=
 +
==Mini fluorescent==
 +
Mini [[Fluorescent Lighting|fluorescent strips]] are a good idea, but are sometimes supplied with less than pleasant bulbs, such as 4000K. [[Fluorescent Lighting|Fluorescent]] gives good even illumination, but beware of going overboard on light level, and check the points above for a good fl lighting installation.
  
* except that regs now mandate an RCDed feed for bathroom lighting on new installs
+
Some mini fl tubes are standardised, some are not. If you choose ones that aren't, you're liable to be tied to that supplier for the life of the installation, which is not a great position to be in. These tubes often leave you no ability to choose any other CCT or CRI.
** except with TT earthing, where everything is fed via RCD.
 
  
 +
Standardised mini fl tubes tend to come in a very limited range of CCT and CRI, and might not be what you want. Many produce not a very good light quality.
  
==Dedicated Freezer Feed==
+
==Large fluorescent==
A freezer is best put on its own dedicated feed, so other appliance faults dont stop it working and ruin £££ of food and days of your cooking efforts. Don't have any RCD on the freezer supply when possible. To meet 16th edn regs, this means the socket for the freezer should not be likely to be used by outdoor tools, so don't put the socket by the back door.
+
A single long T8 or T12 tube can be used to light a whole run of worktop. The tube would be anything from 4' to 8' long. A dimmable ballest is necessary when doing this, full power output would be far too high. Notches are cut in the underside of the cupboards to enable the one tube to span a whole run. The tube is mounted only on clips, with the electronic ballast being placed elsewhere out of view - the popular fully self contained fluorescent fittings aren't suitable, being far too bulky for this use.
  
 +
This has a few advantages:
 +
* Linear fluorescent is the most energy efficient of all domestic lighting types
 +
* Large fl tubes are more energy efficient than small ones
 +
* Dimmability (without sacrificing energy efficiency) gives for comfortable subdued evening lighting, high brightness for cleaning, whatever level you want any time. This gives further energy savings
 +
* One 20,000 hour tube requires a tube replacement 1/4 as often as a set of 4x 20k hour smaller tubes.
 +
* a wide range of CCT and CRI tubes are available, making getting good ones relatively easy.
 +
* Large tubes are standardised and popular, and whatever type you prefer is readily available from a huge number of suppliers
 +
* A long tube can be over the sink without any potential electrical safety issue from water splash.
  
==Sockets==
+
==Halogen==
You need enough. Double sockets are not adequate by themselves to run the amount of electronics we use today (the last socket I put in was a 12 way). On the other hand, installing lagre numbers of fixed sockets is an eyesore and expensive. Doubles are enough if you sprinkle them around the room, and dont mind using many 4 & 6 way extension leads.
+
[[Halogen Lighting|Halogen]] worktop lighting is prone to causing glare. Its high source intensity causes relatively bright reflections on any surface not 100% dead matt.
  
 +
Halogen is more efficient than GLS filament, but not by much. It uses much more energy than CFL or fl.
  
==Halogen Lighting==
+
Low voltage halogen with toughened glass covers eliminate any possible risk from water splash onto mains lighting. Halogen capsules without glass covers are an explosion risk, and should not be used.
I dont recommend halogen downlighters. They're expensive to run, are one of the most energy inefficient options available, heat the house up in summer, they make lying right back in your own home truly uncomfortable, and they tend to give uneven illumination and glare. Halogen lights are also the type most capable of starting fires, and most halogen downlighters pierce the ceiling plasterboard fire and smoke barrier.
 
  
Its wise to calculate run costs before installing halogen, to avoid regret. As an example, 500w of halo downlighters on 6 hours a day would cost £65 per year per room in electricity, plus 12-24 bulb replacements per year at £1 each, making a total cost of £77 per room per year. 4 rooms of this would equal £308 per year, or £9000 per 30 year product life*. The actual amount will depend how much you install. For some people that cost is fine, but for some its not the best way to spend the money.
+
==Tubular filament==
 +
[[image:Tubular_filament_lamp_0090-6.jpg|right|190px]]
  
For those tempted by halogen, I would suggest using lower power halogen downlighters, eg 5w, 10w or 20w, and making up the rest of the light level with better light sources, such as uplighting or concealed lighting.
+
Tubular filament lighting is especially energy inefficient, much more so than GLS filament lighting. Hence it produces more heat than other lighing types, often gradually discolouring kitchen units and warming stored food.  
  
Avoid mains voltage halogens below 150w. Mains bulbs are lower efficiency compared to low voltage ones, more fragile, shorter lived, and more susceptible to early failures. They're also more cost per bulb. For lights under 150w, always choose low voltage.
+
Tubular filament lights also have safety issues. As well as both ends being open to touch, one of which is live, if you touch one end of the tube while inserting the other you can get a shock, and this is easy to do if not paying full attention for a moment.  
  
* Its actually more complex than that, the figure given just gives some idea of what those new halogen fittings will really cost.
+
Tubular filament have short lives of 1000 hours, so lots of bulb changes are required. The design issues inherent in such lamps give them a low colour temperature, ie a slight yellow tendency to the white light.
  
 +
Poor energy efficiency plus the cost of the bulbs make this the most expensive worktop lighting option of all. Its hard to find a reason to install such a historic lighting type today.
  
==Switchbanks==
+
==CFL==
Use switchbanks where possible. These are 2 or more switches in the one box, where one would traditionally find a single switch. Each switch controls some of the lighting. Thus it is easy to control lighting brightness. Cost is about £1 more per switch point, they typically save this much in under a year.  
+
[[image:That CFL 5418-3.jpg|thumb]]
  
The easy ability to adjust brightness significantly improves both living comfort and utility, saves energy, and reduces cost of energy and hassle of replacement bulbs.
+
Flat CFLs are designed for this job, and provide a very energy efficient solution. But replacemant lamps aren't as cheap as most CFLs.
  
Using dimmers to achieve a similar result results in much greater electricity use, as bulb efficiency falls very rapidly with dimming.
+
The lightspread is not quite as even as linear fl, but one significant advantage is that the end user can easily adjust the light level to suit personal preference by replacing bulbs with different wattages.
  
 +
====CFLs of other types====
 +
[[image:Testco11WStickCFL.jpg|thumb]]
  
==Uplighters==
+
Ordinary [[CFL]] worktop lighting is the cheapest option to install, and the second cheapest to run (linear [[Fluorescent Lighting|fluorescent]] only is more energy efficient). The lightspread is not quite as even as linear fl, but one significant advantage is that the end user can easily adjust the light level to suit personal preference by replacing bulbs with different wattages.
If you want uplighting, which is often a good approach, I can reommend using spotlight fittings with ordinary GLS bulbs or CFLs in, not spotlight bulbs. The fittings need to shroud the bulb of course.
 
  
Dont use those 'orrible plaster uplighters, they're inappropriate for uplighting. They create a high intensity light patch on the wall, which uplighting is intended to avoid. They light the wall from such a shallow angle as to magnify and illuminate even the tiniest blemish, making the wall look a mess.
+
Installing CFL lighting is simple and cheap. Pendant bulbholders may be mounted in large-ish holes drilled in the vertical dividers that comprise the bottom part of the sides of the cabinets. A holesaw is used. 40p per bulbholder, plus it uses up those low wattage lamps people have no other use for.
  
Avoid halogen uplighters, they quickly ignite any paper or plastic that lands on them, or that they land on, and there are too many deaths in house fires.
+
==LED==
 +
[[image:800px-E27 with 38 LCD.jpg|thumb|Mains LED lamp]]
  
 +
* LEDs are very small, and LED lighting can be completely hidden under kitchen cabinets.
 +
* LED tape can work well in kitchens
 +
* The most robust lighting type
 +
* LEDs (other than mains LED bulbs) require a power supply unit designed for LED lighting
 +
* LEDs are much more efficient than filament lighting, similar to CFL or linear fluorescent.
 +
* Life expectancy of 10k - 15k hours sounds good, but is often not achieved. And using more LEDs than with other light types brings mean relamping interval down a fair bit.
 +
* White LEDs have a wide range of CCT & CRI, which can disappoint iif you don't know what you want.
 +
* Coloured LEDs can be mixed to produce white light if wished. However getting the proportions of each colour right to produce a good white requires some paperwork, and care with light mixing is needed to avoid coloured shadows.
 +
* LEDs lend themselves very well to dimming.
 +
* Mixed colour LEDs can be switchbanked to enable use of 1 or 2 colours only for mood lighting.
 +
* Mixing 4 LED colours rather than 3 (R,O,G,B) works out cheaper per lumen, since it makes more use of the highest cost blue LEDs. It also allows a wider range of colour options from a simple switchbank.
 +
* Mounting flat LEDs on ali strip cools them, increasing life expectancy.
  
==Kitchen worktop lighting==
+
=[[Fluorescent Lighting]]=
Mini fluorescent strips are a good idea, but are sometimes supplied with poor quality bulbs, such as 4000K, which really don't look good. Fluorescent tubes come in a wide range of different whites, usually named either by colour temperature in K, or by established names such as warm white, daylight, cool white, etc.
+
[[image:Fluorescentfixture.jpg|thumb|Linear Fluorescent]]
  
 +
[[Fluorescent Lighting]] can look good if chosen and installed well. But the all too common choice of a bare bulbed butt ugly glowstart fitting in the centre of the room with a tube chosen at random is a recipe for unpleasant lighting.
  
==Fluorescent Lighting==
+
Good [[Fluorescent Lighting|fluorescent lighting]] needs the following points:
Fluorescent lighting can look good if chosen and installed well. But the all too common choice of a bare bulbed butt ugly glowstart fitting in the centre of the room with a tube chosen at random is a recipe for unpleasant lighting.
 
  
Good fluorescent lighting needs the following points:
 
 
1 Hidden fittings & hidden bulb.
 
1 Hidden fittings & hidden bulb.
2 Uplighting
+
 
 +
2 [[Uplighters|Uplighting]]
 +
 
 
3 comfortable light level.  
 
3 comfortable light level.  
 +
 
4 No flicker and flash
 
4 No flicker and flash
 +
 
5 A tube of respectable quality. I like 3500K tubes, there are several good types to choose from, but there are also many unpleasant or poor quality types of tube on the market.
 
5 A tube of respectable quality. I like 3500K tubes, there are several good types to choose from, but there are also many unpleasant or poor quality types of tube on the market.
 +
 
6 Spare tubes of a size that makes keeping a spare practical.
 
6 Spare tubes of a size that makes keeping a spare practical.
  
1 & 2 - use trough fittings.
 
3 - Choose around a quarter the power you would use with filament bulbs.
 
4 - An electronic ballast fitting avoids all the flicker and flash of cheap glowstart fittings.
 
5 - see the next section
 
6 - 2 foot tubes are easiest to store, 4' are next best. I would not normally recommend larger tubes for domestic use.
 
  
 +
For 1 & 2 - trough fittings are effective.
 +
 +
For 3 - fluorescent lighting should be around a quarter of the power you would use with filament bulbs.
 +
 +
For 4 - An electronic ballast fitting avoids all the flicker and flash of cheaper glowstart fittings.
 +
 +
For 5 - see the next section
 +
 +
For 6 - 2 foot tubes are easiest to store, 4' are next best. Larger tubes provide more light in one place than is usually wanted for domestic use, and spares take a lot of space to store.
  
==Fluorescent tube types==
+
=Fluorescent tube types=
There are many different versions of white, ranging from excellent quality to dire. Buying tubes at random is liable to give you unsatisfactory lighting.
+
[[Fluorescent Lighting|Fluorescent tubes]] come in many different versions of white, ranging from excellent quality to dire. Buying tubes at random is liable to give unsatisfactory lighting.
 
Tubes are normally marked with their colour on on the glass at one end. Many shop assistants are unaware that there are different versions of white, or that the tubes are thus marked, you generally have to look for yourself.
 
Tubes are normally marked with their colour on on the glass at one end. Many shop assistants are unaware that there are different versions of white, or that the tubes are thus marked, you generally have to look for yourself.
  
 
Tubes marked simply as 'white' are not of the best quality, though not the worst.
 
Tubes marked simply as 'white' are not of the best quality, though not the worst.
I can recommend 2700K and 3500K tubes, but I don't recommend higher colour temperature tubes for household use.
+
I can recommend 2700K and 3500K tubes work well in domestic settings. Higher colour temperature tubes appear too cold or harsh for general household use.
2700K is the colour of GLS filament bulbs, so it matches perfectly with traditional filament lighting. 2700K is a warm slightly yellowy white.
+
 
3000K is the colour of halogen bulbs, cleaner and crisper than 2700K. Some 3000K tubes dont have good CRI*, so if you want 3000K to match halogen its best to pick the more expensive triphosphor tubes rather than halophosphates.
+
'''2700K''' is the colour of GLS filament bulbs, so it matches traditional filament [[lighting]]. 2700K is a warm white with a slight tendency to yellowiness. 2700K is less efficient than cooler tints, and not stocked in most shops. 2700K triphosphor is the tube of choice where the fluorescent lighting must take on the character of filament lighting.
3500K will not match other light sources, unless theyre also 3500K fluorescent, but used alone they give a clean fresh and slightly cool look. These are my favourite halophosphate tubes for domestic lighting.
+
 
4000K look cold and anaemic, and 4500K and up are like the old fashioned 'cool white' tubes that once gave fluorescent lighting such a bad reputation.
+
'''3000K''' is the colour temperature of many [[Halogen Lighting|halogen bulbs]], cleaner and crisper than 2700K. Some 3000K fluorescent tubes don't have good CRI*, so if you want 3000K to match halogen its best to pick the more expensive triphosphor tubes rather than halophosphates.
 +
 
 +
'''3500K''' will not match other light sources, unless they're also 3500K [[Fluorescent Lighting|fluorescent]], but used alone they give a clean fresh look. These are my favourite halophosphate tubes for domestic lighting.
 +
 
 +
'''4000K''': cold, harsh and anaemic, and 4500K and up are like the old fashioned 'cool white' tubes that once gave [[Fluorescent Lighting|fluorescent lighting]] such a bad reputation.
 +
 
 
There are also proprietary numbering systems, such as the Philips system.
 
There are also proprietary numbering systems, such as the Philips system.
'Cool white' and 'daylight' are unsuited to domestic use.
 
  
* CRI = colour rendering index, a measurement of how well fluorescent tubes render colour. 100 is perfect, 50 is pretty grim. Triphosphor tubes have higher CRI than halophosphate, but cost more.
+
'''Cool white''' and '''daylight''' are ill suited to domestic use.
  
  
==Filament Strip Lights==
+
<nowiki>*</nowiki> CRI = colour rendering index, a measurement of how well [[Fluorescent Lighting|fluorescent tubes]] render colour. 100 is perfect, 50 is grim. Triphosphor tubes have higher CRI than halophosphate, but cost more.
Do not install filament strip lights. Filament strip bulbs are around a foot long, and rated 30w and 60w. These are very cheap to buy but have particularly poor energy efficiency, unnecessarily high run cost, and the bulbs need frequent replacement. They were popular before WW2, and should have been left there. Flourescent strips will have much lower power ratings, since they're several times more efficient.
 
  
 +
For more information see [[Fluorescent Lighting]]
  
==Kitchen worktop lighting==
+
=Filament Strip Lights=
Fluorescent gives good even illumination, but dont go overboard on light level, and check the points above for a good fl lighting installation.
+
[[image:Tubular_filament_lamp_0090-6.jpg|right|250px]]
 +
Filament strip bulbs are around a foot long, and rated 30w and 60w. The fittings are very cheap to buy, but have particularly poor energy efficiency, unnecessarily high run cost, and the bulbs need frequent replacement.
  
Halogen worktop lighting is prone to causing glare.
+
Both ends of the fitting are open to touch when the bulb is removed, one end is live when on, and also often live when off.
  
Tubular filament lighting is especially energy inefficient, and runs hot, often discolouring kitchen units and heating stored food.
+
These lights also suffer from their own particular safety problem. When inserting a bulb, if you touch the end of the tube that is out of the fitting, you have a 50% chance of being personally connected to the mains. This is due to a few factors with these fittings that combine to make them of poor safety.
  
CFL worktop lighting is cheaper to install than linear fluorescent in cases where there is enough room to fit them. The lightspread is not as even as linear fl, but the end user can very easily adjust the light level to suit personal preference by replacing bulbs.
+
There are 2 ways this can happen. Firstly [[Lamp Life|relamping]] while switched on gives this scenario a 50/50 probability of causing electric shock, and its very easy to end up with a finger on the wrong part of the bulb, it only takes a brief moment of paying attention to something else.
  
 +
Secondly, [[Lamp Life|relamping]] is not always safe while switched off either, as the fittings frequently use non-polarised connectors with single pole switches, as well as having the bare live end and conductive tube with separated connections problems.
  
==Stair Lighting==
+
Tubular filament lamps were in use in the 1920s, and with nothing but disadvantages compared to any other lighting type, their time is up. Fluorescent strips will have much lower power ratings, since they're several times more efficient, and won't fry the kids.
 +
 
 +
=Stair Lighting=
 
It is a wise idea to arrange stair lighting so that the failure of any one light does not jeopardise safety. Stairs cause many injuries & fatalities each year. If lights have overlapping lighting areas, the loss of one light is not a real problem.
 
It is a wise idea to arrange stair lighting so that the failure of any one light does not jeopardise safety. Stairs cause many injuries & fatalities each year. If lights have overlapping lighting areas, the loss of one light is not a real problem.
  
Do not install stair lights out of reach, this is a recipe for a serious accident, inconvenient, and a poor design choice common in times past. It causes falls down stairs while replacing bulbs, delays in bulb replacement, and the elderly and chronically infirm are too often ripped off with exorbitant charges for simply replacing a lightbulb that they can't reach.
+
Installing stair lights out of reach is unwise, this is a recipe for a serious accident, inconvenient, and a poor design choice common in times past. It causes falls down stairs while replacing bulbs, delays in bulb replacement, and the elderly and chronically infirm are too often ripped off with exorbitant charges for simply replacing a lightbulb that they can't reach (eg £50 callout charge). And most of us will be elderly one day.
  
==Emergency lighting==
+
Connecting different stair lights to different lighting circuits ensures [[lighting]] stays in service if/when one of the circuits trips. When there is only one stair light, it can be connected to a different circuit to whichever other light fitting gives the most light to the stairs.
Interior stairwells with no windows benefit from battery backup lights as used for fire escape. Non-maintained units only come on when power is lost, and cost around £17 each.
 
  
Such a light fitted by the CU is a convenient option when money is no object, but a torch or candle fumbled for in the dark is cheaper.
 
  
 +
=[[Emergency Lighting]]=
 +
[[Image:Emergency_light_0994-7.jpg|right|190px]]
  
==MCB Type==
+
Stairwells with no windows benefit from battery backup lights (as used for fire escape). [[Emergency Lighting|Non-maintained]] units only come on when power is lost, and cost around £17.
Lighting can be on type C MCBs rather than the more common type B. Some installs suffer frequent nuisance trips when bulbs blow, the risk of this is a little lower with a type C MCB. MCBs cost about £6 each, and the average 2.5 bed house will have 2 or maybe 3 lighting mcbs. Larger buildings will have more.
 
  
==Light Switch Controls Plugged in Lamps==
+
Such a light fitted by the CU is also a nice option when money is no object, but a torch or candle fumbled for in the dark is cheaper.
It is possible at extra cost to provide wall sockets powered by the wall lightswitch, so standard lamps and table lamps all switch off in one go. Due to technical complications these will usually be 2A or 5A round pin sockets.
 
  
You can either fit a round pin plug on the light or use a round to square pin adaptor. The latter are difficult to find used, as have not seen significant use in decades, but can be made from a plug, socket and flex.
+
=[[MCB]] Type=
 +
[[image:Mcbs.jpg|right|190px]]
  
2A plugs look nicer than 5A imho. 2A equates to a power limit of approx 500w per plug.
+
[[Lighting]] can be on type C [[MCB]]s rather than the more common type B. Some installs suffer frequent nuisance trips when bulbs blow, the risk of this is possibly a little lower with a type C or D [[MCB]]. Care should be taken to ensure the circuit is tested and figures compared with those in the current edition of BS7671 for maximum Zs. [[MCB]]s of either type cost around £6 each, and the average 2.5 bed house will have 2 or maybe 3 lighting [[MCB]]s.
  
 +
Lighting circuits on [[Fuse|rewirable]] or HRC [[fuse]]s pretty much eliminate the false trip problem, but [[Fuse|rewirable fuses]] can be abused by irresponsible people, so these are better avoided in rented accomodation etc.
  
==Cutting costs==
+
=Light Switch Controls Plugged in Lamps=
If necessary, the cost of a professional rewire may be trimmed by the house owner cutting all the chases and routing all the wire as pencilled in by the electrician. For more serious savings, do the whole job yourself. News:uk.d-i-y can help explain things, and avoid common design mistakes. Its fair to say there are some folk that should not do it themselves.
+
It is possible at extra cost to provide wall sockets powered by the wall lightswitch, so standard lamps and table lamps all switch off in one go. Due to technical & legislative issues these will usually be 2A or 5A round pin sockets.
  
 +
A round pin plug can be fitted to the light, or an adaptor used. The latter are almost impossible to find, as they've not seen significant use in decades, but can be made from a plug, socket and flex.
  
==Cost of Rewiring when Buying a House==
+
2A plugs look nicer than 5A imho. 2A gives a power limit of 480w per plug.
Dont overlook the fact that channelling wiring causes considerable damage and mess, and requires redecoration. Dont forget to cost this in when buying a house.
 
  
  
==Listed & Character Buildings==
+
=Cutting costs=
The damage caused by rewiring can sometimes be a real problem in listed, period & other character buildings. In these it is important not to damage or destroy features. In such situations it may be wise to use a written agreement regarding wire routing and damage with your installer. With listed buildings it may be wise to explain to your installer that damaging certain features could constitute a criminal offence. If in doubt about rewiring a listed building, consult your CO first.
+
If necessary, the cost of a professional rewire may be trimmed by the house owner cutting all the chases and routing all the cable as pencilled in by the electrician. Or DIYing the job can make a major saving. [[Newsgroups|News:uk.d-i-y]] can help explain things, and avoid common design mistakes. Its fair to say though that there are some folk that should not do it themselves. Leave 8" or so poking out at each end.
  
When it is desirable to keep period electrical features, this can be done legally and safely, but it is not as simple as just connecting them up. There are a few ways to do it, but this is a subject for another article.
+
=Cost of Rewiring when Buying a House=
 +
Channelling for wiring causes considerable damage and mess, and requires redecoration. Don't forget to cost this in when buying a house.
  
==CFL Light Quality==
 
CFL energy saving bulbs are available in a wide range of qualities. Some produce excellant quality light, copying filament bulbs faithfully, and are very long lived, some produce a pinkish so-so quality light, and some are simply unacceptable (often 6000K or more, and found in pound shops). This variation has led to a reputation for substandard light quality. Try different brands to see whats good, trying one of each initially. The other pitfall to avoid with CFLs is the misleading wattage equivalances quoted on the packs. Real power equivalence ratio is at best 4x, so ignore the pack claims and use 15-18w to replace 60w, and 25w to replace 100w.
 
  
 +
=Listed & Character Buildings=
 +
The damage caused by rewiring can sometimes be a real problem in listed, period & other character buildings. In these it is important not to damage or destroy features. In such situations it may be wise to use a written agreement regarding wire routing and damage with your installer. With listed buildings it may be wise to explain to your installer that damaging certain features would be a criminal offence, and that the installation may be inspected. If in doubt about rewiring a listed building, consult your CO (conservation officer) first. Ignoring the issue can land you with the cost of correctiion works later.
  
==Futureproof Fitting Choices==
+
When it is desirable to keep period electrical features, this can be done legally and safely, but it is not as simple as just connecting them up, and its specialist work. There are a few ways to do it, but this is a subject for another article.
Pick light fittings that will take either GLS or CFL. That way there will be no need to replace light fittings, whatever the future may bring. CFLs are generally larger, and not all fittings will accomodate them. R80 spotlight fittings are not ideal: although avavilable in CFL form, these CFLs are very expensive at over £20 a bulb. There are also £8 ones available, but these have lower light output, and are a bit larger, making the fitting look like the bulb is falling out as well as dim.
 
  
  
==Bulb Bases, BC ES & Miniatures==
+
=CFL Light Quality=
ES screw in bulbs generally cost more than BC Bayonet bulbs, and ES are prone to jams and breakages, and very rarely, bulbs falling out. ES sockets kill more people than BC. So BC is generally preferred.
+
[[CFL]] energy saving bulbs are available in a wide range of qualities. Some produce excellent quality light, copying filament bulbs faithfully, and are very long lived, some produce a pinkish so-so quality light, and some are simply unacceptable (sometimes with CCT of 6000K or more). This variation has led to a reputation for substandard light quality. The easiest way is to try different brands to see what's good, trying one of each initially.  
  
Low power miniature base bulbs (SES, SBC, E14 etc) are generally higher priced than ES and BC, and not always as widely available, so are best only used when there is a reason for them.
+
The other pitfall to avoid with [[CFL]]s is the misleading wattage equivalences quoted on the packs. Real power equivalence ratio is 3-4x, so one can ignore the pack claims and use at least 15-18w to replace 60w, and 25w to replace 100w.
  
==Bulb selection==
 
A good house lighting design will use a small variety of bulbs, making stock keeping easy. All will be easily obtained and easily stored bulb types. Ideally they will also all be low cost high efficiency types. Tubular filament bulbs, PAR38s and large fluorescent tubes (8', 5') will not be used. Nor will relatively uncommon sizes (6', 3')
 
  
 +
=Futureproof Fitting Choices=
 +
Lighting is likely to change over the course of the installation's life. Filament bulbs escaped being banned, but either filament or [[CFL]] may yet fall out of favour for domestic lighting. And [[LED Lighting|LEDs]] might reach the point where they become the prime choice for a lot of domestic lighting.
  
==Relamping Access==
+
Picking light fittings that can take either GLS or [[CFL]] helps avoid problems later. That way there will be no need to replace light fittings, whatever the future may bring. CFLs are generally larger, and not all fittings can accommodate them.
All fittings should be readily accessible so that relamping is easy and safe. The temporary loss of one light should not cause any real problem.  
 
  
 +
R80 spotlight fittings are not ideal: although available in [[CFL]] form, many R80 CFLs are very expensive at over £20 a bulb. There are also £6-8 ones available, but these have lower light output, and in some cases other issues too.
  
==Outdoor Security Lighting==
+
=Bulb Bases=
A common mistake is to use a 500w halogen when 100w or 150w would be more appropriate. Blinding burglars does not seem to make them see the light.
+
[[image:4 Bulb bases 5359-3.jpg|right|190px]]
  
Place your PIR light directly above the door rather than away from it. This way the visitor's face is lit, yours is not, and you're not looking towards a light bulb, but they are. This maximises your security on all 4 points.
+
ES (screw in) bulbs generally cost more than BC (Bayonet cap) bulbs, and ES are prone to jams and breakages, and very rarely, bulbs falling out. ES sockets have rarely killed people, whereas BC haven't so far. So BC has all the advantages.
  
If your door is a short distance from the pavement in town, use a PIR detector with a short range to avoid unnecessary repetitive triggering. If your door opens direct onto the pavement, but is set back a foot or more, use an infrared beam-break trigger rather than PIR or always on. If you have a porch that opens onto a pavement, putting a PIR high up inside the porch on the small sction of wall at the front can shield the pavement from its view.
+
Low power miniature base bulbs (SES, SBC, E14 etc) are generally higher priced than ES and BC, are not always as widely available, and require the stocking of more bulb types. So these are best only used when there is a reason for them.
  
Ideally position PIR sensors so they dont gaze at the sun, they dont look at lights they control, and approaching visitors walk across their field of view. If you dont meet these recommendations they will usually work, but sometimes performance problems can occur. If your situation means you have to ignore all 3 recommendations, it may work fine, but don't blame the manufacturer if it doesn't behave quite as well as expected.
+
SES and SBC lampholders must not be used on circuits >6A, so some people recommend not using 10A lighting circuits in dwellings, as an unskilled person might fit an SBS or SBC decorative fitting at a later date. 6A [[MCB|mcbs]] with 1.5mm^2 cable (rated for >10A) gives the best of all options.
  
Finally, don't forget to set the adjustments on a PIR once its installed. Sensitivity adjustment determines how close someone has to be before it triggers, and dawn/dusk adjustment determines at what daylight level it stops switching on. It is a little optimistic to expect units to come correctly preadjusted.
+
=Bulb selection=
 +
A good house lighting design will use a small variety of bulbs, making stock keeping easy. All will be easily obtained and easily stored bulb types. Ideally they will also all be low cost high efficiency types.  
  
 +
Ideally the following types will not be used:
 +
* Tubular filament bulbs - very poor energy efficiency, safety issues
 +
* PAR38s - some of the most expensive domestic filament lamps available, and with very little advantage over R80 and R90.
 +
* [[Fluorescent Lighting|fluorescent tubes]] in large sizes (5', 8') - awkward to store, produce too much light in one place for most domestic uses
 +
* [[Fluorescent Lighting|fluorescent tubes]] in relatively uncommon sizes (6', 3') - harder to find the wanted tube type.
  
==Tree & Shrub Lighting==
+
5' tubes are however useful for garage and workshop lighting, and spares can be stored there.
Lights among clumps of bushes or up trees can be pretty, but the wiring is more expensive than putting it on the wall, and has more chance of failure.  Halogen capsules should not be fitted near foliage, as halogen capsules run at very high temperatures and are a fire risk. Outdoor wire runs should be on their own circuit, with their own fuse or mcb & RCD. The reason for this is failure rates are higher than with indoor wiring, and wiring them onto existing indoor circuits can therefore cause trouble and expense.
 
  
==CFLs outdoors==
 
CFLs are ill suited to PIR use, but well suited to lights that stay on.
 
When using CFLs outdoors, the type with their own built in glass jacket is preferred, as these are better able to maintain sufficient temperature to keep light output up, and are to some extent more robust. Note that CFLs used outdoors in very cold weather will light at reduced brightness and be slow to warm up. Some CFLs are better suited to outdor use than others, try a few and use the ones that work well in cold weather, or find one specified for outdoor use.
 
  
 +
=Relamping Access=
 +
All fittings should be readily accessible so that [[Lamp Life|relamping]] is easy and safe. The temporary loss of one light should not cause any safety problem or inconvenience.
  
==Outdoor Wiring==
 
SWA cable should be used in preferance to MICC, as MICC is prone to fail outdoors from water ingress.
 
  
 +
=Outdoor Security Lighting=
 +
[[image:Garden light 5367-2.jpg|thumb]]
  
==Making Outdoor Lighting Look Good==
+
A common mistake is to use a 500w [[Halogen Lighting|halogen]] when 100w or 150w would be more appropriate. Blinding burglars does not seem to make them see the light.
 +
 
 +
Placing your [[Dimmed PIR Lights|PIR]] light directly above the door rather than away from it means the visitor's face is lit, yours is not, and you're not looking towards a light bulb, but they are. This maximises your security on all 4 points.
 +
 
 +
If the door is a short distance from the pavement in town, a PIR detector with a short range can avoid unnecessary repetitive triggering. If the door opens direct onto the pavement, but is set back a foot or more, an infrared beam-break trigger may be the only way to avoid frequent false alarms, and uses much less energy than an always on light. These are not popular today, but may be obtained from security suppliers. If you have a porch that opens onto a pavement, putting a PIR high up inside the porch on the small sction of wall at the front can shield the pavement from its view.
 +
 
 +
Ideally position PIR sensors so they dont gaze at the sun, they don't look at lights they control, and approaching visitors walk across their field of view. If you don't meet these recommendations they will usually work, but sometimes performance problems can occur. If your situation means you have to ignore all 3 recommendations, it may work fine, but don't blame the manufacturer if it doesn't behave perfectly.
 +
 
 +
Finally, don't forget to set the adjustments on a PIR once its installed. Sensitivity adjustment determines how close someone has to be before it triggers, and dawn/dusk adjustment determines at what daylight level it stops switching on. Its a little optimistic to expect all units to come correctly pre-adjusted.
 +
 
 +
=Tree & Shrub Lighting=
 +
Lights among clumps of bushes or up trees can be pretty, but the wiring is more expensive than putting it on the wall, and has more chance of failure.  [[Halogen Lighting|Halogen capsules]] should not be fitted near foliage, as halogen capsules run at very high temperatures and are a fire risk. Outdoor wire runs should be on their own circuit, with their own [[fuse]] or [[MCB|mcb]] & [[RCD]]. The reason for this is failure rates are higher than with indoor wiring, and wiring them onto existing indoor circuits can therefore cause unnecessary trouble and expense.
 +
 
 +
 
 +
=CFLs outdoors=
 +
[[CFL]]s are generally ill suited to PIR use, but well suited to lights that stay on.
 +
When using CFLs outdoors, the type with their own built in glass/polycarbonate cover is preferred, as these are better able to maintain sufficient temperature to keep light output up, and are to some extent more robust.
 +
 
 +
[[CFL]]s used outdoors in very cold weather will light at reduced brightness and be slow to warm up. Some CFLs are better suited to outdoor use than others. Use CFLs specified for outdoor use, or maybe just try a few and use the ones that work ok in cold weather.
 +
 
 +
LEDs are now a much better choice for outdoor use. They don't care about being cold.
 +
 
 +
=[[Taking electricity outside|Outdoor Wiring]]=
 +
 
 +
[[Cables|SWA]] (steel wire armoured) or [[Cables|Hi-Tuff]] cable should be used in preference to [[Cables|MICC]] (Mineral Insulated Copper Clad), as MICC is hygroscopic.
 +
 
 +
[[Taking electricity outside|Outdoor wiring]] should be on its own RCBO (or [[RCD]]), since the failure rate of outdoor wiring is much higher than [[House Wiring for Beginners|indoor wiring]]. If both were on the same [[RCD]], RCBO, [[MCB]] or [[fuse]], failure of the [[Taking electricity outside|outdoor wiring]] would also cause failure of the indoor circuit to which it was connected.
 +
 
 +
=Making Outdoor Lighting Look Good=
 
2 or 3x 40w & 60w lights tend to look much better than one 100 or 150 watter. Lights among foliage look much nicer than bare lights. These 2 simple tips make the difference between bare & functional and pretty lighting.
 
2 or 3x 40w & 60w lights tend to look much better than one 100 or 150 watter. Lights among foliage look much nicer than bare lights. These 2 simple tips make the difference between bare & functional and pretty lighting.
  
  
==Beware of some Outdoor Light Fittings==
+
=Outdoor Light Fitting Corrosion=
When picking outdoor lights, beware of cast aluminium lights with steel cover fixing screws, as the cover screws are especially liable to corrode solid. If cast ali fittings are wanted, look for another way to secure the lids on if you want them to last. Wire ties and plastic screws are usually workable options.
+
When picking outdoor lights, beware of cast aluminium lights with steel cover fixing screws, as the cover screws are likely to corrode solid. If cast ali fittings are used, use another way to secure the lids on if you want them to last. Wire ties or plastic [[screws]] are usually workable options.
 +
 
 +
 
 +
=Checking Competence=
 +
Is your electrician competent? Many are, but there are certainly some that aren't. If you wish you can ask them a question or two and check the answers. This also has the benefit of politely letting any cowboys know you might check on their work, which will be offputting to some. An example question might be: What [[Earthing Types|earthing system]] will I get?
 +
 
 +
 
 +
=Low Voltage Wiring=
 +
[[image:Cat5e 4349-3.jpg|right|200px]]
 +
 
 +
There are several reasons to incorporate [[Low Voltage Wiring|low voltage wires]] when rewiring. Increasing use of internet and [[networking|computer networking]], electronic security, more efficient and comfortable separately zoned heating control, the convenience of phone sockets in any room you want them, hifi distribution, all these can be accomodated by incorporating [[Low Voltage Wiring|LV wiring]] into the house.
 +
 
 +
Cat 5e is currently the best option for computer connectivity. No doubt this will change in future, but 5e is the existing standard expected to remain in use the longest, mainly due to its widespread use. Cat5e is also good for phone extensions (which may pass broadband signals now or in future). Either [[Low Voltage Wiring|multicore burglar alarm cable]] or cat5e can also be used for security, door bell, intercom, Lv heating control, baby monitoring, backup lighting, fire detector interconnection, and who knows what other apps will become popular in future.
 +
 
 +
A 50m reel of [[Low Voltage Wiring|multicore LV cable]] is very cheap at around £16, so some people are now incorporating this wiring when they rewire. If choosing between multicore (alarm cable) and cat5e, 5e has more potential uses and can carry faster data, so is the better option. Also bear in mind that some systems using low speed multicore today may well be using standard computer networking protocols in years to come, requiring network cable.
 +
 
 +
While cable cost for LV wiring is cheap, the labour required is not so cheap. Ways to cut costs down are discussed in the main article, [[Low Voltage Wiring]].
 +
 
 +
 
 +
==Conduit==
 +
Some people install conduit for low voltage wiring. This allows future upgrade of cabling as computer speeds increase over the years (I still remember wondering why anyone would need 10M ethernet),
 +
 
 +
There is a variation on this idea that may seem a little odd, but has some merit. The plan is to install the cabling _outside_ of the conduit instead of in it, leaving the conduit with just one wire in. The result of this is that
 +
# Now there is more conduit space in which to thread additional cables should they be wanted
 +
# In future when faster network cables are installed, the old cable stays behind in the plaster, again not taking up any conduit space, but able to be used for various other uses. Having one less cable in the conduit means space for one more cable. (Unused cable in plaster can be left there unused without causing any issues)
 +
 
 +
See the main article [[Low Voltage Wiring]]
 +
 
 +
=Night Lighting=
 +
Built in nightlighting reduces night time accidents and avoids dazzle. 3w [[CFL]]s and 1&3w [[LED]]s are effective. A lampholder can be fitted in most rooms, or less conveniently plug in lights may be used.
 +
 
 +
Low power [[Low Voltage Wiring|low voltage cable]] supplying [[LED Lighting|LEDs]] in each room is also an option.
 +
 
 +
=Fear of the Dark=
 +
For small children, a 3w [[CFL]] bathroom light left on can make life easier for them. This can be fitted either as a separate fitting, or a bathroom globe type light taking 2 bulbs can be used with a twin wall switch. This is a lot less unpleasant for grownups in the night as well. Run cost if left on 24/7 is about £2.50 per year. 1&3w LED lights are an option now as well.
  
 +
=Flush or surface mount=
 +
Electrical accessories are usually recessed into the wall so they sit nearly flush. This looks better and avoids them being a problem with placement of furniture.
  
==Checking Competence==
+
Surface mounted wiring and accessories are a cheaper option, but in most cases don't look particularly good.  
Is your electrician competent? Many are, but there are certainly some that arent. If you wish you can ask them a question or 2 and check the answers. This also has the benefit of politely letting any cowboys know you might check on their work, which will be offputting to some. An example question might be: What earthing system will I get?
 
  
==Low Voltage Wiring==
+
This choice is simple, but if you didn't know what you wanted you could end up with the cheap option without realising what was being agreed.
There are several reasons to incorporate low voltage wires when rewiring. Increasing use of internet and computer networking, electronic security, more efficient and comfortable separately zoned heating control, the convenience of phone sockets in any room you want them, hifi distribution, all these can be accomodated by incorporating LV wiring into the house. Cat 5e is currently the best option for computer connectivity. No doubt this will change in future, but 5e is the standard expected to remain in use the longest, mainly due to its widespread use. Either multicore burglar alarm cable or cat5e can also be used for security, phone, door bell, intercom, Lv heating control, baby monitoring, backup lighting, fire detector interconnection, and who knows what other apps will become popular in future.
 
  
A 100m reel of multicore LV cable is very cheap at around £10, so some are now incorporating this wiring when they rewire. The labour required is not so cheap.
 
  
 +
=Bare Stone walls=
 +
Exposed stone walls are difficult to wire in a way that looks good.
 +
* Copper [[Cables|MICC]] (Mineral-insulated copper-clad) cable can be run low on the wall and left to oxidise and turn a dull colour. This is the best of the straightforward options.
 +
* [[Cables|PVC cable]] can be painted to stand out less. Someone with basic art skills could even camouflage it.
 +
* Burying the wiring in the mortar between 2 layers of stone is an extreme option. This will often mean using a metal sheathed wire, which will take work to shoehorn into an uneven line.
 +
* Low voltage light fittings can be fed from 2 cores of [[Low Voltage Wiring|enamelled copper wire]], which is by far the least visible of all wire types. This can be surface mounted without it being noticeable. It can also be buried under the surface or run in cracks and gaps. 12v [[CFL]]s, filament lamps and halogens are all available. To use mains light fittings at low voltage, the bulbholders in them need to be replaced.
 +
* Flush floor mounted sockets can sometimes be used to eliminate wiring on the wall.
 +
* Wiring can be run in modified wooden skirting board incorporating sheet steel between wood and cable.
 +
* If you're brave you can make a feature out of wiring. This is difficult to make work aesthetically, but it has been achieved at times. Halogen spots clipped onto 2 thick steel [[cables]] is a now classic example of this.
  
==Night Lighting==
+
=Get it in writing=
Built in nightlighting reduces night time accidents and avoids night time dazzling. Low power low voltage cable can supply LEDs in each room, though there are other ways to do it too. This is not one of the cheapest options to have installed. Using mains 3w CFLs in is a reasonable alternative.
+
Unless you just want 'whatever,' is best to get any features you specifically want in writing. Otherwise you may find what you get is not what you agreed on or paid for.
  
  
==Get it in writing==
+
=See Also=
Unless you just want 'whatever,' you should get any features you specifically want in writing. Otherwise you may find what you get is not what you paid for.
+
* [[Bad Ideas - Lighting]]
 +
* [[Bad Ideas - Electrical]]
 +
* [[Fluorescent Lighting]]
 +
* [[RCD]]
 +
* [[Dimmed PIR Lights]]
 +
* [[Halogen Lighting]]
 +
* [[Historic Mains Cables|Old Wiring]]
 +
* [[Discharge Lighting]]
 +
* [[Low Voltage Wiring]]
  
  
==See Also==
+
=Disclaimer=
[[Old Wiring]]
+
You and only you are responsible for your actions. There's no point blaming me or us later if you did something not addressed by this, or misunderstood and mis-implemented, acted on an error or omission, or followed this advice and got unsatisfactory results. This writing is not intended to replace the advice of a skilled electrician that has seen your house and discussed your specific requirements, and can only be general and limited in nature. It will however enable many people to get significantly better installations and avoid some common causes of accidents and unnecessary trouble & expense.
[[Discarge Lighting]]
 
[[Fluorescent Lighting]]
 
[[RCD]]
 
  
 +
NT 2006
  
==Disclaimer==
+
[[Category:Electrical]]
You and only you are responsible for your actions. There's no point blaming me or us later if you did something not addressed by this, or misunderstood and misimplemented, acted on an error or omission, or followed this advice and got unsatisfactory results. This writing is not intended to replace the advice of a skilled electrician that has seen your house and discussed your specific requirements, and can only be general and limited in nature. It will however enable many people to get significantly better installations and avoid some common causes of accidents and unnecessary trouble & expense.
+
[[Category:Lighting]]

Latest revision as of 22:06, 28 September 2019

Lots of useful information for anyone due to rewire.

This article collects together some of the options and suggestions for improving the functionality of any new wiring system. It does not include details of the mechanics of installing wiring. For that please see the Electrical Installation article.


The Basics

The basic electrical installation design is fairly much decided by the 17th edition wiring regs which came into force on 1 July 2008 , so unless you get into specialist, unusual or illegal territory, many of the choices are already made for you.

You're still left with quite a lot of details to choose from. These details can affect comfort, safety, reliability, and avoid unnecessary trouble and expense. In sum these many details can make quite a difference. A lot of good choices can be made at little or no cost, and several will save money.


The Basic System

You'll get 32A ring circuits supplying the sockets, or occasionally 20A radials. You'll get 6A lighting circuits, or occasionally 10A. You'll get dedicated feeds for cooker and shower if you've got those, or the oven might end up on a 13A plug.

You'll normally get at least 1 RCD, which in a small minority of cases can produce a lot of frustration by frequently taking out the power (see nuisance trips).


Glossary

CU: consumer unit, the modern version of a fusebox.

Split load CU: A CU divided into at least 2 sections, each with its own main switch or RCD. A good idea. It means power can stay on no matter what happens to one section of the wiring. Even during a partial rewire sections of the power can stay on.

MCB: a pushbutton overcurrent trip found in the consumer unit. This replaces a fuse. Although now unpopular, Rewirable fuses are still fully compliant with today's wiring regs. Contrary to popular myth, MCBs are not a significant safety benefit for general use, but they are easier to reset. Where they are a safety plus is when householders can be expected to be irresponsible, eg rented property. MCBs should be chosen in these cases, as rewirable fuses are easy to abuse.

RCD: earth leakage trip found in the consumer unit. This will trip if earth leakage current is too high, and reduces the risk of electrocution. Unfortunately they're known for nuisance trips, especially when configured with a single device protecting all the circuits (a so called "whole house" RCD). The majority of old installs have no RCD.

TT: a type of earthing that uses a local earth rod. TT installations require all circuits to be RCD protected since an earth rod alone is usually inadequate to clear earth faults.

The Choices

Now some ideal choices. Many will add a bit to installation cost, but are well worth it. Many cost nothing extra, and a few cost a lot. One can make many good choices without adding a lot to the cost.


Split Load CU

Use of a split load CU means one some of your wiring can be turned off while the rest stays on. So whatever may happen with your electrical system*, you don't need to turn it all off. This enables you to have power in the event of a fault, and to have power while working on the installation itself. Split load CUs are common today (especially with wiring compliant with the 17th edition of the wiring regs) Typical extra cost: £0

*there are exceptions of course, such as lightning strike or a major fire.


RCDs

RCDs are almost universal in new installs. See the RCD System Notes article for details of how to design a system to make best use of these.

What you don't want is the deprecated install of one RCD supplying half or even the whole house. While many of these work OK, some create no end of frustration, trouble and expense for the householder. For £35-£100 more you can have 2 or 3 RCBOs instead of one RCD, which eliminates many RCD nuisance trips, and minimises the consequences of any that do occur. This way if an RCD trips, you lose power to one socket circuit instead of all power.

Historically, (unless you had a TT earthing system), lighting would usually not be on an RCD. Lighting circuits have not proven to be a significant electrocution risk in themselves. The cable protection requirements of the 17th edition (not to mention the bathroom electrics one) will tend to mean that lighting circuits are now protected by RCDs. Hence its wise to design your system to mitigate any risks of unexpected loss of lighting that could result.

Dedicated Freezer Feed

A freezer is best put on its own dedicated feed installed in non RCD protected way of the consumer unit, so other appliance faults don't stop it working and ruin £££ of food and days of your cooking efforts, or risk food poisoning.

The risks of food poisoning from poor storage far outweigh those of shock from freezers, so no RCD on the freezer supply is the safer option.

  1. To meet 16th edn regs, this means the socket for the freezer should not be likely to be used by outdoor tools, so don't put the socket by the back door.
  2. The 17th edition, does not preclude a non-RCD socket for fridge/freezers provided the cable installation
  • is either surface mounted or follows the rules a-d listed here Cables in a wall or partition
  • and the socket is clearly labelled for fridge/freezer use only.


The next best option is to use a feed from a dedicated RCBO on a non RCD protected section of the consumer unit. This may still trip due to earth leakage caused by a faulty fridge or a damaged cable, but won't be tripped by faults on other circuits.

Sockets

13A double socket.jpg

You need enough. Double sockets are not adequate by themselves to run the amount of electronics we use today (the last socket I put in was a 12 way). On the other hand, installing large numbers of fixed sockets is an eyesore and expensive. Doubles are enough if you sprinkle them around the room, and don't mind using several 4 & 6 way extension leads.

If the cable for the socket circuit is run round most of the room at socket height, its relatively easy to add more sockets in future wherever you need them.

Halogen Lighting

Halogen reflector lamp
Halogen capsule lamp

Halogen downlighters are popular today, but have some downsides. They're expensive to run, are one of the most energy inefficient options available, heat the house up in summer, they make lying right back in your own home truly uncomfortable, and they tend to give uneven illumination and glare. Halogen lights are also the type most capable of starting fires, and most halogen downlighters pierce the ceiling plasterboard fire and smoke barrier. There are approx 69,000 house fires per year in the UK.

Its a good idea to calculate run costs before installing halogen, to avoid regret. As an example, 500w of halogen downlighters on 6 hours a day would cost £65 per year per room in electricity, plus 12-24 bulb replacements per year at £1 each, making a total cost of £77 per room per year. 4 rooms of this would equal £308 per year, or £9000 per 30 year product life*. For comparison, a similar level of CFL lighting would cost around £2000. (The exact amount will depend how much you install.) For some people that cost is fine, but for some its not the best way to spend the money.

For those that want the look of halogen without the energy use, there is the option to use lower power halogen downlighters, eg 5w, 10w or 20w, making up the rest of the light level with more efficient light sources, such as uplighting or concealed lighting.

Below 150w, mains voltage halogens are less efficient and less reliable than 12v halogen. Mains bulbs are lower efficiency compared to low voltage ones, more fragile, shorter lived, and more susceptible to early failures. They're also more cost per bulb. Low voltage does cost slightly more to install, but the extra cost is repaid many times over in use.

* Its actually more complex than that, and needs to be calculated for each case. The figure given just gives some idea of what those new halogen fittings will really cost.

Switchbanks

Switchbank

Fitting switchbanks where possible improves comfort and reduces electricity bills a little. These are 2 or more switches in the one box, where one would traditionally find a single switch. Each switch controls some of the lighting. Thus it is easy to control lighting brightness. Cost is about £1 more per switch point, and they typically save this much in under a year.

The easy ability to adjust brightness significantly improves both living comfort and utility, saves energy, and reduces cost of energy and hassle of replacement bulbs.

Using dimmers to achieve a similar result results in much greater electricity use, as bulb efficiency falls very rapidly with dimming. It may also cause practical problems if filament bulbs are banned, which looks fairly likely, as dimmers are incompatible with most other lamp types.

Uplighters

R80 Uplighter

Uplighting uses the ceiling as a large diffuse source of light for the room. This gives less shadows and dark spots and more even illumination, than other lighting types, and better energy efficiency than downlighting. With white ceilings of at least normal height, uplighting is a good approach to general lighting.

For uplighting, spotlight fittings with ordinary GLS bulbs or CFLs in (not spotlight bulbs) are effective, look good, work well, and minimise bulb cost. Such fittings need to shroud the bulb. For large uplighters, PAR38 spotlight fittings that wrap around the bulb work well, again using GLS or CFL bulbs, not PARs.

Plaster uplighters are not recommended, really they're inappropriate for uplighting. They create a high intensity light patch on the wall, which uplighting is intended to avoid. They light the wall from such a shallow angle as to magnify and illuminate even the tiniest blemish, making the wall look a mess.

Halogen uplighters are a particular risk, they quickly ignite any paper or plastic that lands on them, or that they land on, and there are already too many deaths in house fires.

Kitchen worktop lighting

Mini fluorescent

Mini fluorescent strips are a good idea, but are sometimes supplied with less than pleasant bulbs, such as 4000K. Fluorescent gives good even illumination, but beware of going overboard on light level, and check the points above for a good fl lighting installation.

Some mini fl tubes are standardised, some are not. If you choose ones that aren't, you're liable to be tied to that supplier for the life of the installation, which is not a great position to be in. These tubes often leave you no ability to choose any other CCT or CRI.

Standardised mini fl tubes tend to come in a very limited range of CCT and CRI, and might not be what you want. Many produce not a very good light quality.

Large fluorescent

A single long T8 or T12 tube can be used to light a whole run of worktop. The tube would be anything from 4' to 8' long. A dimmable ballest is necessary when doing this, full power output would be far too high. Notches are cut in the underside of the cupboards to enable the one tube to span a whole run. The tube is mounted only on clips, with the electronic ballast being placed elsewhere out of view - the popular fully self contained fluorescent fittings aren't suitable, being far too bulky for this use.

This has a few advantages:

  • Linear fluorescent is the most energy efficient of all domestic lighting types
  • Large fl tubes are more energy efficient than small ones
  • Dimmability (without sacrificing energy efficiency) gives for comfortable subdued evening lighting, high brightness for cleaning, whatever level you want any time. This gives further energy savings
  • One 20,000 hour tube requires a tube replacement 1/4 as often as a set of 4x 20k hour smaller tubes.
  • a wide range of CCT and CRI tubes are available, making getting good ones relatively easy.
  • Large tubes are standardised and popular, and whatever type you prefer is readily available from a huge number of suppliers
  • A long tube can be over the sink without any potential electrical safety issue from water splash.

Halogen

Halogen worktop lighting is prone to causing glare. Its high source intensity causes relatively bright reflections on any surface not 100% dead matt.

Halogen is more efficient than GLS filament, but not by much. It uses much more energy than CFL or fl.

Low voltage halogen with toughened glass covers eliminate any possible risk from water splash onto mains lighting. Halogen capsules without glass covers are an explosion risk, and should not be used.

Tubular filament

Tubular filament lamp 0090-6.jpg

Tubular filament lighting is especially energy inefficient, much more so than GLS filament lighting. Hence it produces more heat than other lighing types, often gradually discolouring kitchen units and warming stored food.

Tubular filament lights also have safety issues. As well as both ends being open to touch, one of which is live, if you touch one end of the tube while inserting the other you can get a shock, and this is easy to do if not paying full attention for a moment.

Tubular filament have short lives of 1000 hours, so lots of bulb changes are required. The design issues inherent in such lamps give them a low colour temperature, ie a slight yellow tendency to the white light.

Poor energy efficiency plus the cost of the bulbs make this the most expensive worktop lighting option of all. Its hard to find a reason to install such a historic lighting type today.

CFL

That CFL 5418-3.jpg

Flat CFLs are designed for this job, and provide a very energy efficient solution. But replacemant lamps aren't as cheap as most CFLs.

The lightspread is not quite as even as linear fl, but one significant advantage is that the end user can easily adjust the light level to suit personal preference by replacing bulbs with different wattages.

CFLs of other types

Testco11WStickCFL.jpg

Ordinary CFL worktop lighting is the cheapest option to install, and the second cheapest to run (linear fluorescent only is more energy efficient). The lightspread is not quite as even as linear fl, but one significant advantage is that the end user can easily adjust the light level to suit personal preference by replacing bulbs with different wattages.

Installing CFL lighting is simple and cheap. Pendant bulbholders may be mounted in large-ish holes drilled in the vertical dividers that comprise the bottom part of the sides of the cabinets. A holesaw is used. 40p per bulbholder, plus it uses up those low wattage lamps people have no other use for.

LED

Mains LED lamp
  • LEDs are very small, and LED lighting can be completely hidden under kitchen cabinets.
  • LED tape can work well in kitchens
  • The most robust lighting type
  • LEDs (other than mains LED bulbs) require a power supply unit designed for LED lighting
  • LEDs are much more efficient than filament lighting, similar to CFL or linear fluorescent.
  • Life expectancy of 10k - 15k hours sounds good, but is often not achieved. And using more LEDs than with other light types brings mean relamping interval down a fair bit.
  • White LEDs have a wide range of CCT & CRI, which can disappoint iif you don't know what you want.
  • Coloured LEDs can be mixed to produce white light if wished. However getting the proportions of each colour right to produce a good white requires some paperwork, and care with light mixing is needed to avoid coloured shadows.
  • LEDs lend themselves very well to dimming.
  • Mixed colour LEDs can be switchbanked to enable use of 1 or 2 colours only for mood lighting.
  • Mixing 4 LED colours rather than 3 (R,O,G,B) works out cheaper per lumen, since it makes more use of the highest cost blue LEDs. It also allows a wider range of colour options from a simple switchbank.
  • Mounting flat LEDs on ali strip cools them, increasing life expectancy.

Fluorescent Lighting

Linear Fluorescent

Fluorescent Lighting can look good if chosen and installed well. But the all too common choice of a bare bulbed butt ugly glowstart fitting in the centre of the room with a tube chosen at random is a recipe for unpleasant lighting.

Good fluorescent lighting needs the following points:

1 Hidden fittings & hidden bulb.

2 Uplighting

3 comfortable light level.

4 No flicker and flash

5 A tube of respectable quality. I like 3500K tubes, there are several good types to choose from, but there are also many unpleasant or poor quality types of tube on the market.

6 Spare tubes of a size that makes keeping a spare practical.


For 1 & 2 - trough fittings are effective.

For 3 - fluorescent lighting should be around a quarter of the power you would use with filament bulbs.

For 4 - An electronic ballast fitting avoids all the flicker and flash of cheaper glowstart fittings.

For 5 - see the next section

For 6 - 2 foot tubes are easiest to store, 4' are next best. Larger tubes provide more light in one place than is usually wanted for domestic use, and spares take a lot of space to store.

Fluorescent tube types

Fluorescent tubes come in many different versions of white, ranging from excellent quality to dire. Buying tubes at random is liable to give unsatisfactory lighting. Tubes are normally marked with their colour on on the glass at one end. Many shop assistants are unaware that there are different versions of white, or that the tubes are thus marked, you generally have to look for yourself.

Tubes marked simply as 'white' are not of the best quality, though not the worst. I can recommend 2700K and 3500K tubes work well in domestic settings. Higher colour temperature tubes appear too cold or harsh for general household use.

2700K is the colour of GLS filament bulbs, so it matches traditional filament lighting. 2700K is a warm white with a slight tendency to yellowiness. 2700K is less efficient than cooler tints, and not stocked in most shops. 2700K triphosphor is the tube of choice where the fluorescent lighting must take on the character of filament lighting.

3000K is the colour temperature of many halogen bulbs, cleaner and crisper than 2700K. Some 3000K fluorescent tubes don't have good CRI*, so if you want 3000K to match halogen its best to pick the more expensive triphosphor tubes rather than halophosphates.

3500K will not match other light sources, unless they're also 3500K fluorescent, but used alone they give a clean fresh look. These are my favourite halophosphate tubes for domestic lighting.

4000K: cold, harsh and anaemic, and 4500K and up are like the old fashioned 'cool white' tubes that once gave fluorescent lighting such a bad reputation.

There are also proprietary numbering systems, such as the Philips system.

Cool white and daylight are ill suited to domestic use.


* CRI = colour rendering index, a measurement of how well fluorescent tubes render colour. 100 is perfect, 50 is grim. Triphosphor tubes have higher CRI than halophosphate, but cost more.

For more information see Fluorescent Lighting

Filament Strip Lights

Tubular filament lamp 0090-6.jpg

Filament strip bulbs are around a foot long, and rated 30w and 60w. The fittings are very cheap to buy, but have particularly poor energy efficiency, unnecessarily high run cost, and the bulbs need frequent replacement.

Both ends of the fitting are open to touch when the bulb is removed, one end is live when on, and also often live when off.

These lights also suffer from their own particular safety problem. When inserting a bulb, if you touch the end of the tube that is out of the fitting, you have a 50% chance of being personally connected to the mains. This is due to a few factors with these fittings that combine to make them of poor safety.

There are 2 ways this can happen. Firstly relamping while switched on gives this scenario a 50/50 probability of causing electric shock, and its very easy to end up with a finger on the wrong part of the bulb, it only takes a brief moment of paying attention to something else.

Secondly, relamping is not always safe while switched off either, as the fittings frequently use non-polarised connectors with single pole switches, as well as having the bare live end and conductive tube with separated connections problems.

Tubular filament lamps were in use in the 1920s, and with nothing but disadvantages compared to any other lighting type, their time is up. Fluorescent strips will have much lower power ratings, since they're several times more efficient, and won't fry the kids.

Stair Lighting

It is a wise idea to arrange stair lighting so that the failure of any one light does not jeopardise safety. Stairs cause many injuries & fatalities each year. If lights have overlapping lighting areas, the loss of one light is not a real problem.

Installing stair lights out of reach is unwise, this is a recipe for a serious accident, inconvenient, and a poor design choice common in times past. It causes falls down stairs while replacing bulbs, delays in bulb replacement, and the elderly and chronically infirm are too often ripped off with exorbitant charges for simply replacing a lightbulb that they can't reach (eg £50 callout charge). And most of us will be elderly one day.

Connecting different stair lights to different lighting circuits ensures lighting stays in service if/when one of the circuits trips. When there is only one stair light, it can be connected to a different circuit to whichever other light fitting gives the most light to the stairs.


Emergency Lighting

Emergency light 0994-7.jpg

Stairwells with no windows benefit from battery backup lights (as used for fire escape). Non-maintained units only come on when power is lost, and cost around £17.

Such a light fitted by the CU is also a nice option when money is no object, but a torch or candle fumbled for in the dark is cheaper.

MCB Type

Mcbs.jpg

Lighting can be on type C MCBs rather than the more common type B. Some installs suffer frequent nuisance trips when bulbs blow, the risk of this is possibly a little lower with a type C or D MCB. Care should be taken to ensure the circuit is tested and figures compared with those in the current edition of BS7671 for maximum Zs. MCBs of either type cost around £6 each, and the average 2.5 bed house will have 2 or maybe 3 lighting MCBs.

Lighting circuits on rewirable or HRC fuses pretty much eliminate the false trip problem, but rewirable fuses can be abused by irresponsible people, so these are better avoided in rented accomodation etc.

Light Switch Controls Plugged in Lamps

It is possible at extra cost to provide wall sockets powered by the wall lightswitch, so standard lamps and table lamps all switch off in one go. Due to technical & legislative issues these will usually be 2A or 5A round pin sockets.

A round pin plug can be fitted to the light, or an adaptor used. The latter are almost impossible to find, as they've not seen significant use in decades, but can be made from a plug, socket and flex.

2A plugs look nicer than 5A imho. 2A gives a power limit of 480w per plug.


Cutting costs

If necessary, the cost of a professional rewire may be trimmed by the house owner cutting all the chases and routing all the cable as pencilled in by the electrician. Or DIYing the job can make a major saving. News:uk.d-i-y can help explain things, and avoid common design mistakes. Its fair to say though that there are some folk that should not do it themselves. Leave 8" or so poking out at each end.

Cost of Rewiring when Buying a House

Channelling for wiring causes considerable damage and mess, and requires redecoration. Don't forget to cost this in when buying a house.


Listed & Character Buildings

The damage caused by rewiring can sometimes be a real problem in listed, period & other character buildings. In these it is important not to damage or destroy features. In such situations it may be wise to use a written agreement regarding wire routing and damage with your installer. With listed buildings it may be wise to explain to your installer that damaging certain features would be a criminal offence, and that the installation may be inspected. If in doubt about rewiring a listed building, consult your CO (conservation officer) first. Ignoring the issue can land you with the cost of correctiion works later.

When it is desirable to keep period electrical features, this can be done legally and safely, but it is not as simple as just connecting them up, and its specialist work. There are a few ways to do it, but this is a subject for another article.


CFL Light Quality

CFL energy saving bulbs are available in a wide range of qualities. Some produce excellent quality light, copying filament bulbs faithfully, and are very long lived, some produce a pinkish so-so quality light, and some are simply unacceptable (sometimes with CCT of 6000K or more). This variation has led to a reputation for substandard light quality. The easiest way is to try different brands to see what's good, trying one of each initially.

The other pitfall to avoid with CFLs is the misleading wattage equivalences quoted on the packs. Real power equivalence ratio is 3-4x, so one can ignore the pack claims and use at least 15-18w to replace 60w, and 25w to replace 100w.


Futureproof Fitting Choices

Lighting is likely to change over the course of the installation's life. Filament bulbs escaped being banned, but either filament or CFL may yet fall out of favour for domestic lighting. And LEDs might reach the point where they become the prime choice for a lot of domestic lighting.

Picking light fittings that can take either GLS or CFL helps avoid problems later. That way there will be no need to replace light fittings, whatever the future may bring. CFLs are generally larger, and not all fittings can accommodate them.

R80 spotlight fittings are not ideal: although available in CFL form, many R80 CFLs are very expensive at over £20 a bulb. There are also £6-8 ones available, but these have lower light output, and in some cases other issues too.

Bulb Bases

4 Bulb bases 5359-3.jpg

ES (screw in) bulbs generally cost more than BC (Bayonet cap) bulbs, and ES are prone to jams and breakages, and very rarely, bulbs falling out. ES sockets have rarely killed people, whereas BC haven't so far. So BC has all the advantages.

Low power miniature base bulbs (SES, SBC, E14 etc) are generally higher priced than ES and BC, are not always as widely available, and require the stocking of more bulb types. So these are best only used when there is a reason for them.

SES and SBC lampholders must not be used on circuits >6A, so some people recommend not using 10A lighting circuits in dwellings, as an unskilled person might fit an SBS or SBC decorative fitting at a later date. 6A mcbs with 1.5mm^2 cable (rated for >10A) gives the best of all options.

Bulb selection

A good house lighting design will use a small variety of bulbs, making stock keeping easy. All will be easily obtained and easily stored bulb types. Ideally they will also all be low cost high efficiency types.

Ideally the following types will not be used:

  • Tubular filament bulbs - very poor energy efficiency, safety issues
  • PAR38s - some of the most expensive domestic filament lamps available, and with very little advantage over R80 and R90.
  • fluorescent tubes in large sizes (5', 8') - awkward to store, produce too much light in one place for most domestic uses
  • fluorescent tubes in relatively uncommon sizes (6', 3') - harder to find the wanted tube type.

5' tubes are however useful for garage and workshop lighting, and spares can be stored there.


Relamping Access

All fittings should be readily accessible so that relamping is easy and safe. The temporary loss of one light should not cause any safety problem or inconvenience.


Outdoor Security Lighting

Garden light 5367-2.jpg

A common mistake is to use a 500w halogen when 100w or 150w would be more appropriate. Blinding burglars does not seem to make them see the light.

Placing your PIR light directly above the door rather than away from it means the visitor's face is lit, yours is not, and you're not looking towards a light bulb, but they are. This maximises your security on all 4 points.

If the door is a short distance from the pavement in town, a PIR detector with a short range can avoid unnecessary repetitive triggering. If the door opens direct onto the pavement, but is set back a foot or more, an infrared beam-break trigger may be the only way to avoid frequent false alarms, and uses much less energy than an always on light. These are not popular today, but may be obtained from security suppliers. If you have a porch that opens onto a pavement, putting a PIR high up inside the porch on the small sction of wall at the front can shield the pavement from its view.

Ideally position PIR sensors so they dont gaze at the sun, they don't look at lights they control, and approaching visitors walk across their field of view. If you don't meet these recommendations they will usually work, but sometimes performance problems can occur. If your situation means you have to ignore all 3 recommendations, it may work fine, but don't blame the manufacturer if it doesn't behave perfectly.

Finally, don't forget to set the adjustments on a PIR once its installed. Sensitivity adjustment determines how close someone has to be before it triggers, and dawn/dusk adjustment determines at what daylight level it stops switching on. Its a little optimistic to expect all units to come correctly pre-adjusted.

Tree & Shrub Lighting

Lights among clumps of bushes or up trees can be pretty, but the wiring is more expensive than putting it on the wall, and has more chance of failure. Halogen capsules should not be fitted near foliage, as halogen capsules run at very high temperatures and are a fire risk. Outdoor wire runs should be on their own circuit, with their own fuse or mcb & RCD. The reason for this is failure rates are higher than with indoor wiring, and wiring them onto existing indoor circuits can therefore cause unnecessary trouble and expense.


CFLs outdoors

CFLs are generally ill suited to PIR use, but well suited to lights that stay on. When using CFLs outdoors, the type with their own built in glass/polycarbonate cover is preferred, as these are better able to maintain sufficient temperature to keep light output up, and are to some extent more robust.

CFLs used outdoors in very cold weather will light at reduced brightness and be slow to warm up. Some CFLs are better suited to outdoor use than others. Use CFLs specified for outdoor use, or maybe just try a few and use the ones that work ok in cold weather.

LEDs are now a much better choice for outdoor use. They don't care about being cold.

Outdoor Wiring

SWA (steel wire armoured) or Hi-Tuff cable should be used in preference to MICC (Mineral Insulated Copper Clad), as MICC is hygroscopic.

Outdoor wiring should be on its own RCBO (or RCD), since the failure rate of outdoor wiring is much higher than indoor wiring. If both were on the same RCD, RCBO, MCB or fuse, failure of the outdoor wiring would also cause failure of the indoor circuit to which it was connected.

Making Outdoor Lighting Look Good

2 or 3x 40w & 60w lights tend to look much better than one 100 or 150 watter. Lights among foliage look much nicer than bare lights. These 2 simple tips make the difference between bare & functional and pretty lighting.


Outdoor Light Fitting Corrosion

When picking outdoor lights, beware of cast aluminium lights with steel cover fixing screws, as the cover screws are likely to corrode solid. If cast ali fittings are used, use another way to secure the lids on if you want them to last. Wire ties or plastic screws are usually workable options.


Checking Competence

Is your electrician competent? Many are, but there are certainly some that aren't. If you wish you can ask them a question or two and check the answers. This also has the benefit of politely letting any cowboys know you might check on their work, which will be offputting to some. An example question might be: What earthing system will I get?


Low Voltage Wiring

Cat5e 4349-3.jpg

There are several reasons to incorporate low voltage wires when rewiring. Increasing use of internet and computer networking, electronic security, more efficient and comfortable separately zoned heating control, the convenience of phone sockets in any room you want them, hifi distribution, all these can be accomodated by incorporating LV wiring into the house.

Cat 5e is currently the best option for computer connectivity. No doubt this will change in future, but 5e is the existing standard expected to remain in use the longest, mainly due to its widespread use. Cat5e is also good for phone extensions (which may pass broadband signals now or in future). Either multicore burglar alarm cable or cat5e can also be used for security, door bell, intercom, Lv heating control, baby monitoring, backup lighting, fire detector interconnection, and who knows what other apps will become popular in future.

A 50m reel of multicore LV cable is very cheap at around £16, so some people are now incorporating this wiring when they rewire. If choosing between multicore (alarm cable) and cat5e, 5e has more potential uses and can carry faster data, so is the better option. Also bear in mind that some systems using low speed multicore today may well be using standard computer networking protocols in years to come, requiring network cable.

While cable cost for LV wiring is cheap, the labour required is not so cheap. Ways to cut costs down are discussed in the main article, Low Voltage Wiring.


Conduit

Some people install conduit for low voltage wiring. This allows future upgrade of cabling as computer speeds increase over the years (I still remember wondering why anyone would need 10M ethernet),

There is a variation on this idea that may seem a little odd, but has some merit. The plan is to install the cabling _outside_ of the conduit instead of in it, leaving the conduit with just one wire in. The result of this is that

  1. Now there is more conduit space in which to thread additional cables should they be wanted
  2. In future when faster network cables are installed, the old cable stays behind in the plaster, again not taking up any conduit space, but able to be used for various other uses. Having one less cable in the conduit means space for one more cable. (Unused cable in plaster can be left there unused without causing any issues)

See the main article Low Voltage Wiring

Night Lighting

Built in nightlighting reduces night time accidents and avoids dazzle. 3w CFLs and 1&3w LEDs are effective. A lampholder can be fitted in most rooms, or less conveniently plug in lights may be used.

Low power low voltage cable supplying LEDs in each room is also an option.

Fear of the Dark

For small children, a 3w CFL bathroom light left on can make life easier for them. This can be fitted either as a separate fitting, or a bathroom globe type light taking 2 bulbs can be used with a twin wall switch. This is a lot less unpleasant for grownups in the night as well. Run cost if left on 24/7 is about £2.50 per year. 1&3w LED lights are an option now as well.

Flush or surface mount

Electrical accessories are usually recessed into the wall so they sit nearly flush. This looks better and avoids them being a problem with placement of furniture.

Surface mounted wiring and accessories are a cheaper option, but in most cases don't look particularly good.

This choice is simple, but if you didn't know what you wanted you could end up with the cheap option without realising what was being agreed.


Bare Stone walls

Exposed stone walls are difficult to wire in a way that looks good.

  • Copper MICC (Mineral-insulated copper-clad) cable can be run low on the wall and left to oxidise and turn a dull colour. This is the best of the straightforward options.
  • PVC cable can be painted to stand out less. Someone with basic art skills could even camouflage it.
  • Burying the wiring in the mortar between 2 layers of stone is an extreme option. This will often mean using a metal sheathed wire, which will take work to shoehorn into an uneven line.
  • Low voltage light fittings can be fed from 2 cores of enamelled copper wire, which is by far the least visible of all wire types. This can be surface mounted without it being noticeable. It can also be buried under the surface or run in cracks and gaps. 12v CFLs, filament lamps and halogens are all available. To use mains light fittings at low voltage, the bulbholders in them need to be replaced.
  • Flush floor mounted sockets can sometimes be used to eliminate wiring on the wall.
  • Wiring can be run in modified wooden skirting board incorporating sheet steel between wood and cable.
  • If you're brave you can make a feature out of wiring. This is difficult to make work aesthetically, but it has been achieved at times. Halogen spots clipped onto 2 thick steel cables is a now classic example of this.

Get it in writing

Unless you just want 'whatever,' is best to get any features you specifically want in writing. Otherwise you may find what you get is not what you agreed on or paid for.


See Also


Disclaimer

You and only you are responsible for your actions. There's no point blaming me or us later if you did something not addressed by this, or misunderstood and mis-implemented, acted on an error or omission, or followed this advice and got unsatisfactory results. This writing is not intended to replace the advice of a skilled electrician that has seen your house and discussed your specific requirements, and can only be general and limited in nature. It will however enable many people to get significantly better installations and avoid some common causes of accidents and unnecessary trouble & expense.

NT 2006