Difference between revisions of "Safe zones for electric cables"
Jump to navigation
Jump to search
ARWadsworth (talk | contribs) |
m (reword) |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | Electric cables are usually run in one of a number of prescribed safe zones. Knowing where these zones are allows you to correctly install cables and help eliminated damage to them when drilling walls at a later date | |
− | |||
− | Electric cables are usually run in prescribed safe zones. Knowing where these zones are allows you to correctly install cables and help eliminated damage to them when drilling walls at a later date | ||
Line 8: | Line 6: | ||
*a horizontal zone within 150mm of the top of a wall | *a horizontal zone within 150mm of the top of a wall | ||
− | *a vertical zone within 150mm of the angle formed by two walls | + | *a vertical zone within 150mm of the angle formed by two walls - e.g. internal and external corners. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | *the horizontal and vertical zone adjacent to an electrical accessory (switch, socket, cable outlet etc) | ||
+ | [[Image:Cablezones1.jpg]] | ||
+ | *where an accessory on the reverse side of the wall can be easily determined, e.g. through a door or archway, and the wall or partition depth is 100mm or less, then the horizontal and vertical zones to that accessory apply to both rooms: | ||
+ | [[Image:Cablezones2.jpg]] | ||
+ | Where cables are not in installed in a safe zone then they need to be installed according to the rules explained [[Cable_Routes_and_Protection|here.]] | ||
+ | =See Also= | ||
+ | * [[Special:Allpages|Wiki Contents]] | ||
+ | * [[Special:Categories|Wiki Subject Categories]] | ||
+ | * [[Cables]] | ||
+ | * [[Electrical Installation]] | ||
− | [[Category: Electrical]] | + | [[Category:Electrical]] |
Latest revision as of 14:25, 1 June 2019
Electric cables are usually run in one of a number of prescribed safe zones. Knowing where these zones are allows you to correctly install cables and help eliminated damage to them when drilling walls at a later date
The safe zones for cables concealed in walls are
- a horizontal zone within 150mm of the top of a wall
- a vertical zone within 150mm of the angle formed by two walls - e.g. internal and external corners.
- the horizontal and vertical zone adjacent to an electrical accessory (switch, socket, cable outlet etc)
- where an accessory on the reverse side of the wall can be easily determined, e.g. through a door or archway, and the wall or partition depth is 100mm or less, then the horizontal and vertical zones to that accessory apply to both rooms:
Where cables are not in installed in a safe zone then they need to be installed according to the rules explained here.