− | + | ==1st edn== | |
+ | 1882, a 4 page document with 21 regulations. At this time bare exposed iron wire was the norm, and joints were made by a long carefully specified twist of the wires. | ||
+ | |||
+ | The initial impetus for these rules was the Phoenix insurance company, who were handling a lot of fire claims due to badly installed arc lights. The early rules were to reduce risk of fire, they did not address shock. | ||
+ | |||
+ | ==2nd edn== | ||
+ | 1888 | ||
+ | ==3rd edn== | ||
+ | 1897 | ||
+ | ==4th edn== | ||
+ | 1903 | ||
+ | ==5th edn== | ||
+ | 1907 | ||
+ | ==6th edn== | ||
+ | 1911 | ||
+ | ==7th edn== | ||
+ | 1916 | ||
+ | ==8th edn== | ||
+ | 1924 | ||
+ | ==9th edn== | ||
+ | 1927 | ||
+ | ==10th edn== | ||
+ | 1934. Earthing required for the first time | ||
+ | ==11th edn== | ||
+ | 1939. Revised to varying degrees in 1943, 45, 46 & 48. | ||
+ | |||
+ | Ring circuits introduced in 1947 | ||
+ | |||
+ | ==12th edn== | ||
+ | 1950. Supplement 1954 | ||
+ | ==13th edn== | ||
+ | 1955 | ||
+ | ==14th edn== | ||
+ | 1966. Earthed lighting circuits required for the first time | ||
+ | ==15th edn== | ||
+ | Released 1981, implemented 1985 | ||
+ | |||
+ | The Electric Lighting Act 1882 was finally repealed in 1989 | ||
+ | |||
+ | ==16th edn== | ||
+ | 1991 or 93 | ||
+ | |||
+ | ==Part P== | ||
+ | 2005 | ||
+ | ==17th edn== | ||
+ | 2008. Amended 2011 | ||
+ | |||
== IEE WIRING REGULATIONS 16TH EDITION == | == IEE WIRING REGULATIONS 16TH EDITION == | ||
+ | '''Old material from the FAQ''' | ||
By Andrew Gabriel 2/3/1998 | By Andrew Gabriel 2/3/1998 | ||
Line 15: | Line 62: | ||
Any bookshop should be able to order these if they don't stock them, or you can order from the IEE's web page above. | Any bookshop should be able to order these if they don't stock them, or you can order from the IEE's web page above. | ||
+ | |||
+ | [[Category:Electrical]] |
Revision as of 16:49, 7 August 2014
1st edn
1882, a 4 page document with 21 regulations. At this time bare exposed iron wire was the norm, and joints were made by a long carefully specified twist of the wires.
The initial impetus for these rules was the Phoenix insurance company, who were handling a lot of fire claims due to badly installed arc lights. The early rules were to reduce risk of fire, they did not address shock.
2nd edn
1888
3rd edn
1897
4th edn
1903
5th edn
1907
6th edn
1911
7th edn
1916
8th edn
1924
9th edn
1927
10th edn
1934. Earthing required for the first time
11th edn
1939. Revised to varying degrees in 1943, 45, 46 & 48.
Ring circuits introduced in 1947
12th edn
1950. Supplement 1954
13th edn
1955
14th edn
1966. Earthed lighting circuits required for the first time
15th edn
Released 1981, implemented 1985
The Electric Lighting Act 1882 was finally repealed in 1989
16th edn
1991 or 93
Part P
2005
17th edn
2008. Amended 2011
IEE WIRING REGULATIONS 16TH EDITION
Old material from the FAQ
By Andrew Gabriel 2/3/1998
Amendment 2 edition (1997) has a yellow cover (original 16th edition has a red cover; amendment 1 (1994) has a green cover). Also known as "Requirements for Electrical Installations" and "BS 7671:1992 Incorporating second amendment"
http://www.iee.org.uk/publish/books/wireregs.html#wireregs
290pp., 297 x 210mm, Soft covers version, ISBN 0 85296 927 9, 1997 UKP 42 / US$ 84
Ring-bound version, ISBN 0 85296 842 6, 1994 UKP 55 / US$ 110
Updates are available to bring a first amendment version up to the second amendment:
For soft covers version, ISBN 0 85296 926 0, 1997 UKP 12 / US$ 24
For ring-bound version, ISBN 0 85296 938 4, 1997 UKP 12 / US$ 24
Any bookshop should be able to order these if they don't stock them, or you can order from the IEE's web page above.