Talk:House Wiring for Beginners: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
bathroom skts |
||
Line 9: | Line 9: | ||
--[[User:John Rumm|John Rumm]] 04:07, 27 May 2007 (BST) | --[[User:John Rumm|John Rumm]] 04:07, 27 May 2007 (BST) | ||
==Bathroom sockets== | |||
AIUI sockets are allowed in bathrooms if they are either | |||
* accessible with use of a tool | |||
* outside zone 3 | |||
Is this incorrect? | |||
[[User:NT|NT]] 12:20, 30 May 2007 (BST) |
Revision as of 11:20, 30 May 2007
Piccie in overview section shows a spur off a radial - you can only have spurs off ring circuits. ;-)
--John Rumm 04:52, 26 May 2007 (BST)
Do explain.... :) NT 08:25, 26 May 2007 (BST)
A branch from a radial is just that, a branch. Its not a spur since that term has a particular definition in BS7671, and spurs also have a set of limitations about how they can be used, that do not apply to radials. Radials do not have to be a linear chain of accessories, any topology is acceptable including multi branch and star.
--John Rumm 04:07, 27 May 2007 (BST)
Bathroom sockets
AIUI sockets are allowed in bathrooms if they are either
- accessible with use of a tool
- outside zone 3
Is this incorrect? NT 12:20, 30 May 2007 (BST)