Difference between revisions of "Earth Cooling Tubes"

From DIYWiki
Jump to navigation Jump to search
(linkify, couple redundant words removed, UK spelling,)
(→‎Mould: link fix)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
'''Earth cooling tubes''' or '''earth warming tubes''' (also known as '''ground-coupled heat exchangers''') use the earth's near constant subterranean temperature to warm or [[:Category:Cooling|cool]] air. They are often a viable and economical alternative to conventional [[:Category:Cooling|air conditioning]] systems or [[Heat Pumps]] since there are no compressors, chemicals or burners and only a fan is required to move the air.
 
'''Earth cooling tubes''' or '''earth warming tubes''' (also known as '''ground-coupled heat exchangers''') use the earth's near constant subterranean temperature to warm or [[:Category:Cooling|cool]] air. They are often a viable and economical alternative to conventional [[:Category:Cooling|air conditioning]] systems or [[Heat Pumps]] since there are no compressors, chemicals or burners and only a fan is required to move the air.
  
Earth tubes are regularly used in some European countries to pre-[[:Category:Heating|heat or pre-cool air for the whole [[:Category:Building|building]] [[Heat Recovery Ventilation]] systems that are used in buildings designed to the German Passive House standard.
+
Earth tubes are regularly used in some European countries to pre-[[:Category:Heating|heat]] or pre-cool air for the whole [[:Category:Building|building]] [[Heat Recovery Ventilation]] systems that are used in buildings designed to the German Passive House standard.
  
  
Line 22: Line 22:
  
 
===Mould===
 
===Mould===
One issue is the possibility of [[:Category:Damp|condensation]] buildup in the tubes and subsequent [[Mouldproof Paint|mould]] growth. A properly designed system that maintains a constant downward slope from the (upper) warm air intake end to the(lower) cool air outlet end should provide adequate drainage of [[:Category:Damp|condensation]] that can be handled by a floor [[:Category:Plumbing|drain]], much like a conventional home [[:Category:Cooling|air conditioning]] system. Also, it is important not to use corrugated or ribbed tubing as this would create traps where moisture would assuredly accumulate.
+
One issue is the possibility of [[:Category:Damp|condensation]] buildup in the tubes and subsequent [[Mould|mould]] growth. A properly designed system that maintains a constant downward slope from the (upper) warm air intake end to the(lower) cool air outlet end should provide adequate drainage of [[:Category:Damp|condensation]] that can be handled by a floor [[:Category:Plumbing|drain]], much like a conventional home [[:Category:Cooling|air conditioning]] system. Also, it is important not to use corrugated or ribbed tubing as this would create traps where moisture would assuredly accumulate.
  
 
While some possibility of mold growth might still be possible, smooth round tubes should be much easier to clean than conventional rectangular metal ductwork found in the average home or office where mould growth is a common and accepted problem.
 
While some possibility of mold growth might still be possible, smooth round tubes should be much easier to clean than conventional rectangular metal ductwork found in the average home or office where mould growth is a common and accepted problem.
  
 
Another option is to use [[Dehumidifiers|dehumidification]] of [[Plumbing|pipe]] air to prevent [[:Category:Damp|condensation]]. Condensate may be returned to the incoming air stream when drying is not desired.
 
Another option is to use [[Dehumidifiers|dehumidification]] of [[Plumbing|pipe]] air to prevent [[:Category:Damp|condensation]]. Condensate may be returned to the incoming air stream when drying is not desired.
 
  
 
==Efficiency==
 
==Efficiency==
Line 42: Line 41:
  
 
==See also==
 
==See also==
[[Special:Allpages|Wiki Contents]]
+
* [[Special:Allpages|Wiki Contents]]
 
+
* [[Special:Categories|Wiki Subject Categories]]
[[Special:Categories|Wiki Subject Categories]]
+
* [http://en.wikipedia.org/wiki/Ground-coupled_heat_exchanger Wikipedia]
 
+
* [http://www.advancedbuildings.org/main_t_vent_underground.htm AdvancedBuildings.org: Ground-coupled heat exchanger]
[http://www.advancedbuildings.org/main_t_vent_underground.htm AdvancedBuildings.org: Ground-coupled heat exchanger]
 
  
  

Latest revision as of 00:40, 9 December 2010

Earth cooling tubes or earth warming tubes (also known as ground-coupled heat exchangers) use the earth's near constant subterranean temperature to warm or cool air. They are often a viable and economical alternative to conventional air conditioning systems or Heat Pumps since there are no compressors, chemicals or burners and only a fan is required to move the air.

Earth tubes are regularly used in some European countries to pre-heat or pre-cool air for the whole building Heat Recovery Ventilation systems that are used in buildings designed to the German Passive House standard.


Design

Most systems are constructed from 4 to 18 inch (100 to 450mm) diameter, smooth-walled, rigid or semi-rigid plastic or metal pipes, buried 6 to 10 feet (1.5 to 3m) underground where the temperature is typically 50-70 °F (10 to 20 °C) all year round.

There are basically three configurations, an open 'fresh air' system, a closed loop design, or a combination:

  • Closed loop system - Air from inside the building is blown through a U-shaped loop(s) of typically 100 to 500 feet (30 to 150m) of tube(s) where it is moderated to near earth temperature before returning to the house. Larger diameter tubes need less total length. The closed loop system is usually more effective than the open system since it cools and recools the same air.
  • Open system - outside air is drawn from a screened outdoor intake through typically 100 feet (30m) or more of tube into the home.
  • Combination system - This can be crafted with unidirectional check valve dampers to allow either closed or open operation depending on the season and/or fresh air ventilation requirements.

Lightweight dampers, when in closed loop mode, could draw a quantity of fresh air when an air pressure drop is created in the house, eg by a fireplace chimney draft. Therefore rigid closures may also be used.


Installation

In new builds, earth tubes may enter the house underground. In retrofits, the tubes will generally come in above ground.

Mould

One issue is the possibility of condensation buildup in the tubes and subsequent mould growth. A properly designed system that maintains a constant downward slope from the (upper) warm air intake end to the(lower) cool air outlet end should provide adequate drainage of condensation that can be handled by a floor drain, much like a conventional home air conditioning system. Also, it is important not to use corrugated or ribbed tubing as this would create traps where moisture would assuredly accumulate.

While some possibility of mold growth might still be possible, smooth round tubes should be much easier to clean than conventional rectangular metal ductwork found in the average home or office where mould growth is a common and accepted problem.

Another option is to use dehumidification of pipe air to prevent condensation. Condensate may be returned to the incoming air stream when drying is not desired.

Efficiency

The energy efficiency of earth cooling tubes can be several times that of air conditioning for a properly designed system.

System efficiency varies significantly depending on tube depth, climate, soil type, soil moisture content and ground level sun or shade. Generally sandy, dry soil with little or no ground level shade will yield the poorest benefit while dense clay or damp loam with considerable shade should perform well. Site selection affects performance. Damp soil absorbs and dissipates the warmth drawn off the tubes better than dry soil.


Benefits

Properly designed earth cooling tubes present an energy efficient lower cost alternative to air conditioning.

They may also be used in conjunction with air source heat pumps for winter heating.


See also