Search results

Jump to navigation Jump to search
  • ...eats faster, as well as the main longer element that produces enough for a shower or [[:Category:Bathrooms|bath]]. # Insufficient HW system capacity for new appliances, eg power shower
    8 KB (1,302 words) - 20:19, 8 September 2018
  • ...s]] are a particular issue in this area. Every single spark in that orange shower is a red hot piece of metal, grit, or whatever you're grinding. And sometim
    5 KB (790 words) - 13:46, 15 April 2009
  • ...irritating, especially if spread over a wide area e.g. descaling a bath or shower cubicle. ==== Shower curtains ====
    10 KB (1,458 words) - 15:57, 7 April 2012
  • * Never stand in a wet puddle again when you get out of the [[showers|shower]]
    5 KB (744 words) - 11:29, 14 September 2009
  • ...oltage) into the room. (Rooms such cloakrooms or toilets without a bath or shower, are not treated as special locations since although there is water, its le ...ng no (supplementary) equipotential bonding in a room containing a bath or shower providing that the main equipotential bonding is in place, and that all the
    12 KB (1,937 words) - 23:06, 31 January 2024
  • * Do you use the bath? Perhaps an instant shower would suit.
    4 KB (613 words) - 22:27, 30 June 2023
  • Imagine we added an additional circuit to feed a 40A shower to the circuits listed in the example above. We would then arrive at the si :* A load like an electric shower one might assume is unlikely to run for more than 12 mins out of every 15,
    9 KB (1,368 words) - 21:41, 29 August 2016
  • ...lly several layers of protection against this occurring with showers, if a shower reaches this point the installation is in a terrible state and may fry you
    3 KB (497 words) - 20:23, 2 September 2018
  • ...nits to BS EN 61558-2-5) to be installed in locations containing a bath or shower 3m horizontally beyond the boundary of zone 1.</span></span> ...orated in Part 7: Section 701 '''</span>Locations containing a bath tub or shower basin.</span>
    17 KB (2,464 words) - 14:55, 18 November 2018
  • ...to 50 degrees too. No bath here, the DHW heater on the combi just ran the shower and an occasional washing up bowl. The flat is over-radiatored with 4-off d So I decide to get rid of the gas forever. The DHW for shower, sink and basin can be done by an instant electric 9kW multi-point. Unlikel
    14 KB (2,541 words) - 16:23, 6 December 2022
  • ...space. It does have a large cupboard, and this would make for a good-sized shower if it were re-purposed. ...and rebuild both rooms. Fortunately there is another fully working loo and shower room downstairs in the house, so that will take some of the time and logist
    48 KB (8,920 words) - 13:07, 28 December 2021
  • ...nd no ability to respond to the changing vapour load of cooking, [[showers|shower]] use & occupancy. Humidistatic units cost more than the cheapest dehumidif ...l in anything from 1 day in severe damp to several days when used to dry a shower room.
    16 KB (2,754 words) - 19:23, 6 November 2022
  • ...bulbs]] run at high pressure and are known to very occasionally explode. A shower of high speed & very high temperature broken bulb pieces is probably not be
    6 KB (887 words) - 21:54, 29 September 2018
  • ...t to prevent these chemicals depositing themselves inside pipes, tanks and shower heads. Nor should it be confused with a water FILTER, which removes bacteri
    6 KB (1,104 words) - 10:59, 7 January 2022
  • *Dedicated high current circuit [[MCB]] & [[Cables|cable]] supplying shower ...D]] on the other. Generally the [[RCD]] side is used to supply sockets and shower, with most other items on the non-RCD side.
    26 KB (4,100 words) - 00:12, 16 September 2021
  • ...r more. The smaller sizes being adequate for properties that have a single shower/bathroom. Larger sizes become more appropriate for larger properties with m ...a cold water outlet point after the pressure reducing valve to supply e.g. shower mixing valves which work better when their hot and cold supplies are at the
    15 KB (2,499 words) - 21:20, 5 May 2021
  • ===Shower=== *Use a low flow shower head
    20 KB (3,343 words) - 11:58, 24 September 2022
  • * A 15 minute shower uses more water than a bath
    7 KB (1,141 words) - 13:44, 7 April 2012
  • ...violations. No problems with lights, fans or sockets too close to a bath, shower or sink. He may find a lack of labels or lack of identifying sleeves on swi
    6 KB (1,076 words) - 18:50, 26 October 2022
  • * Is there a shower pump? Location? How to isolate (electrical and water)?
    8 KB (1,230 words) - 17:29, 21 August 2022
  • ...getting some old carpet and underlay around the cab and I've screwed some shower-tidys on the cab back wall. It'll do for several years, there's not much to
    7 KB (1,256 words) - 23:38, 17 February 2023
  • ...ically designed for hanging towels over for warning and drying in bath and shower rooms. Chrome plated or white painted ladder types are widely available at
    14 KB (2,237 words) - 00:48, 9 December 2010
  • ...e are particularly vulnerable to electrical shock injury, such as bath and shower rooms. Bonding also helps mitigate the risks of conductive parts of a house
    9 KB (1,461 words) - 04:49, 1 December 2012
  • ...how mains powered extractor fans of the type often found in bathrooms and shower rooms can be wired.
    11 KB (1,928 words) - 13:06, 5 January 2024
  • * Hot &amp; Cold water pipes to sink, bath, shower
    11 KB (1,751 words) - 02:17, 6 September 2017
  • ...able of carrying this current. A good example of this would be an electric shower or an immersion heater supply cable where there is no end user action, or t Say we have an electric shower with a design current <math>I_b</math> of 41A, and a cable run of 19m, inst
    23 KB (3,726 words) - 23:12, 31 January 2024
  • ...pipework was brought up to enter the loft through the floor where the new shower is shown on the plan above. In the shower room, I ran in wiring for a humidistat controlled fan, a shaver light, and
    69 KB (12,721 words) - 22:49, 31 January 2024
  • Water resistant adhesive is needed for shower and over bath use. More basic types fall off after a bit.
    10 KB (1,764 words) - 21:08, 24 January 2013
  • ...he wall. I also routed a pipe channel to it. This is in a side-room toilet/shower where the inner lining is plastic 10mm cladding and not metal stud. The dec
    10 KB (1,800 words) - 18:39, 6 November 2021
  • ...wall - say when cutting in electrical accessory boxes, or making access to shower valves. They are also very effective for removing old grout from between ti
    13 KB (2,110 words) - 23:58, 10 September 2018
  • ...ated wood is fine. If the wall is liable to get wet, eg close to a bath or shower, its worth using treated wood.
    20 KB (3,429 words) - 20:52, 1 November 2021
  • ...hot shed in summer unless kept to a small percentage of roof area. A white shower curtain may be fixed underneath to reduce this effect to a degree, and prev
    20 KB (3,173 words) - 19:36, 27 January 2013
  • ...r cylinder really needs a refresh because the lady of the house just had a shower, and that is going to take priority over heat! (not helped because this als
    23 KB (4,272 words) - 22:52, 7 August 2023
  • ...to install but has higher running costs: popular choice for small bath or shower rooms.
    25 KB (4,005 words) - 22:17, 4 November 2021
  • ;Thermostatic Shower : Shower containing a thermostat. Reduces output temperature swings as inlet tempera
    59 KB (8,842 words) - 21:43, 1 November 2021
  • ...g circuits, or occasionally 10A. You'll get dedicated feeds for cooker and shower if you've got those, or the oven might end up on a 13A plug.
    40 KB (6,736 words) - 22:06, 28 September 2019
  • ...er it might still be worth using a combi for the kitchen sink tap and/or a shower and using the heating side to do both heating and heat the HW store/cylind
    50 KB (8,759 words) - 12:00, 24 September 2022

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)