Difference between revisions of "Pullcord switch noise"
(fix cat) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | New '''Pullcord switches''' widely used in bathrooms have become noisy over the last few decades. In some cases they can wake the whole household up at night. | + | New '''Pullcord switches''' widely used in bathrooms have become noisy over the last few decades. In some cases they can wake the whole household up at night. |
==Sound reduction strategies== | ==Sound reduction strategies== | ||
Line 9: | Line 9: | ||
===Mounting point=== | ===Mounting point=== | ||
− | When mounted to | + | When mounted to plasterboard, the board acts as a sounding board, increasing the noise. Its quieter to [[screw]] the switch through to a timber joist, though there isn't always one in the right place. |
===Tablelamp switch=== | ===Tablelamp switch=== | ||
Line 16: | Line 16: | ||
===Rubber mount=== | ===Rubber mount=== | ||
Mounting the switch enclosure to the ceiling with tapwashers helps a lot. | Mounting the switch enclosure to the ceiling with tapwashers helps a lot. | ||
− | * The traditional fixing consists of, in order: ceiling plasterboard, switch enclosure base, screw | + | * The traditional fixing consists of, in order: ceiling plasterboard, switch enclosure base, [[screw]] |
− | * A rubber mounted fixing consists of, in order: ceiling plasterboard, rubber tapwasher, switch enclosure base, rubber tapwasher, large metal washer, screw | + | * A rubber mounted fixing consists of, in order: ceiling plasterboard, rubber tapwasher, switch enclosure base, rubber tapwasher, large metal washer, [[screw]] |
* See [[Fan_noise_reduction#Flexible_mounting]] | * See [[Fan_noise_reduction#Flexible_mounting]] | ||
Line 24: | Line 24: | ||
===Relay=== | ===Relay=== | ||
− | Standard mains wallswitch on 6v operating a relay. | + | Standard mains wallswitch on [[Wallwart|6v]] operating a relay. |
===Switches outside the bathroom=== | ===Switches outside the bathroom=== | ||
Line 33: | Line 33: | ||
===Switch above ceiling=== | ===Switch above ceiling=== | ||
− | Occasionally its possible to mount the switch to timber above the ceiling, and run the pullcord through a very small ceiling hole with a drilled disc on the plasterboard to tidy it up (and stop the cord damaging the plasterboard). Round the edges of the hole to avoid cord damage. This is doable where there's loft access above. | + | Occasionally its possible to mount the switch to timber above the ceiling, and run the pullcord through a very small ceiling hole with a [[Drill bit|drilled]] disc on the plasterboard to tidy it up (and stop the cord damaging the plasterboard). Round the edges of the hole to avoid cord damage. This is doable where there's loft access above. |
===PIR sensor=== | ===PIR sensor=== | ||
Line 40: | Line 40: | ||
==See also== | ==See also== | ||
− | [[ | + | |
− | [[ | + | |
− | [[ | + | |
− | [[ | + | [[Category:Bathrooms]] |
+ | [[Category:Electrical]] | ||
+ | [[Category:Lighting]] | ||
+ | [[Category:Noise]] |
Latest revision as of 08:34, 26 March 2011
New Pullcord switches widely used in bathrooms have become noisy over the last few decades. In some cases they can wake the whole household up at night.
Sound reduction strategies
Pick your switch
These are quieter than average.
Current rating
2A switches are less noisy than 10A ones.
Mounting point
When mounted to plasterboard, the board acts as a sounding board, increasing the noise. Its quieter to screw the switch through to a timber joist, though there isn't always one in the right place.
Tablelamp switch
A 1A tablelamp pullcord switch can be fitted inside a standard pullcord switch enclosure, mounted on rubber tap washers. But these aren't as robust, abuse of the pullcord can break them.
Rubber mount
Mounting the switch enclosure to the ceiling with tapwashers helps a lot.
- The traditional fixing consists of, in order: ceiling plasterboard, switch enclosure base, screw
- A rubber mounted fixing consists of, in order: ceiling plasterboard, rubber tapwasher, switch enclosure base, rubber tapwasher, large metal washer, screw
- See Fan_noise_reduction#Flexible_mounting
Low level lighting
Very low level lighting often avoids the need to use the main light, especially at night when the noise is worst. LED lighting is the obvious candidate, and the lowest power CFLs.
Relay
Standard mains wallswitch on 6v operating a relay.
Switches outside the bathroom
Pullcord switches are then unnecessary. Children can be a nuisance with them.
Pullcord dimmer
Luxury options can be silent, but expensive.
Switch above ceiling
Occasionally its possible to mount the switch to timber above the ceiling, and run the pullcord through a very small ceiling hole with a drilled disc on the plasterboard to tidy it up (and stop the cord damaging the plasterboard). Round the edges of the hole to avoid cord damage. This is doable where there's loft access above.
PIR sensor
Bathroom lights operated by a PIR sensor are sometimes suggested. In practice they result in complaints such as being dazzled by unwanted light at night, and lights going out when busy.