'''Neon [[screwdrivers]]''' are used to test mains circuits to see if they're live. However they have significant problems, and the majority view on [[Newsgroup access tips|uk.d-i-y]] is they're best not used at all.
+
'''Neon [[screwdrivers]]''' are fairly crude and simple instruments that combine the functions of a small terminal screwdriver with a mains voltage detector. Note however, they have a number of potential safety problems, and the majority view on [[Newsgroup access tips|uk.d-i-y]] is that the voltage detection capability is best not used at all.
  
  
 
==How they work==
 
==How they work==
Mains power flows down the screw driving tip to the resistor and neon in the handle. When you touch the brass cap, mains power flows through you, completing the [[House Wiring for Beginners|circuit]] and lighting the neon.
+
Mains power flows down the screw driving tip to the resistor and neon in the handle. When you touch the brass cap, the bodies natural capacitance allows enough power to flow through the screwdriver to cause the neon to light.
  
The currents involved are small enough not to feel, so the normal current level is not a safety concern.
+
The currents involved are very small, so you will not to feel and sense of electric shock under normal circumstances.  
  
  
 
==The Problems==
 
==The Problems==
 +
 
===Direct shock===
 
===Direct shock===
[[Water]] or condensation on the resistor can result in the tool passing higher current to the user, causing a shock, maybe a fall from a ladder, and the slight risk of fatality.
+
[[Water]] or condensation on the resistor can result in the tool passing higher current to the user than intended, causing a shock, maybe a fall from a ladder. Hence never hold one of these screwdrivers in your mouth when working with both hands for example.  
 
 
Certain tool faults such as resistor failure can cause the same problem.
 
  
 +
Certain tool faults such as resistor a failure can create similar risks.
  
 
===False negative===
 
===False negative===
 
The [[lighting]] of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live [[cables|wire]], and this is probably the most common failure mechanism.
 
The [[lighting]] of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live [[cables|wire]], and this is probably the most common failure mechanism.
  
Not being connected to or near earth, eg up a wooden ladder, can reduce current flow further, reducing light output and making the dimness situation worse.
+
Not being connected to or near earth, insulated from ground, can reduce current flow further, reducing light output and making the dimness situation worse. The body being capacitively coupled to some other nearby live conductor, can prevent the light lighting at all, even when the screw driver tips is touching a live wire or contact.  
  
 
===False Positive===
 
===False Positive===
A user capacitively connected to a live supply will light a neon screwdriver touched to any non-live [[cables|wire]]. It is quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a cable, even leaning on a wall in some cases, and so on.
+
A user capacitively connected to a live supply will light a neon screwdriver touched to any non-live [[cables|wire]]. It is quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a cable, even leaning on a wall in some cases, and so on. Also touching a "floating" conductor (i.e. an uncontaminated wire that is routed in close proximity to other live wires) may also yield a false positive test.
  
 +
==Minimising risk / safe use==
 +
If you must use one of these devices, then adobe a sound "prove dead" approach to testing. Before making a test, test the driver on a known live conductor and ensure it lights up. Next test the unknown conductor, and ensure it does not light, Finally test again on a known life conductor.
  
 
===Legality===
 
===Legality===
Because of the issues with these [[Hand Tools|tools]], they are illegal to use at a place of work.
+
There is some question as to whether these [[Hand Tools|tools]], are legal to use in the workplace, since they don't possess a number of the attributes deemed necessary in electrical test gear by the health and safety executive. See the document GS38 [http://www.hse.gov.uk/pubns/priced/gs38.pdf Electrical Test Equipment for Electricians] (PDF) - in particular section 9.
  
  
Line 33: Line 35:
 
[http://groups.google.co.uk/group/uk.d-i-y/browse_frm/thread/007f918ced3f909c?hl=en# uk.d-i-y thread]
 
[http://groups.google.co.uk/group/uk.d-i-y/browse_frm/thread/007f918ced3f909c?hl=en# uk.d-i-y thread]
  
 +
==Alternatives==
 +
A much better alternative is a non contact volt stick:
 +
 +
[[image:VoltStick-2.jpg]]
  
==Alternatives==
+
These can give a clear and unambiguous indication of a live circuit, without even needing to open any insulating cover or make physical contact with the circuit.
Better alternatives include a non contact volt stick, or a [[multimeter]]. A reasonable quality meter will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are less and much more under the control of the end user, so can be minimised with care.
+
 
 +
Other alternatives a [[multimeter]] or other specialist electricians voltage meter. A reasonable quality meter will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are less and much more under the control of the end user, so can be minimised with care.
  
 
==See Also==
 
==See Also==

Revision as of 02:43, 15 March 2012

Phasenpruefer 01-l KMJ.jpg

Neon screwdrivers are fairly crude and simple instruments that combine the functions of a small terminal screwdriver with a mains voltage detector. Note however, they have a number of potential safety problems, and the majority view on uk.d-i-y is that the voltage detection capability is best not used at all.


How they work

Mains power flows down the screw driving tip to the resistor and neon in the handle. When you touch the brass cap, the bodies natural capacitance allows enough power to flow through the screwdriver to cause the neon to light.

The currents involved are very small, so you will not to feel and sense of electric shock under normal circumstances.


The Problems

Direct shock

Water or condensation on the resistor can result in the tool passing higher current to the user than intended, causing a shock, maybe a fall from a ladder. Hence never hold one of these screwdrivers in your mouth when working with both hands for example.

Certain tool faults such as resistor a failure can create similar risks.

False negative

The lighting of the neon is sometimes too dim to see, especially in daylight. The result is shock from touching a live wire, and this is probably the most common failure mechanism.

Not being connected to or near earth, insulated from ground, can reduce current flow further, reducing light output and making the dimness situation worse. The body being capacitively coupled to some other nearby live conductor, can prevent the light lighting at all, even when the screw driver tips is touching a live wire or contact.

False Positive

A user capacitively connected to a live supply will light a neon screwdriver touched to any non-live wire. It is quite easy to be capacitively coupled in this way without noticing. Holding an inspection light, standing on a cable, even leaning on a wall in some cases, and so on. Also touching a "floating" conductor (i.e. an uncontaminated wire that is routed in close proximity to other live wires) may also yield a false positive test.

Minimising risk / safe use

If you must use one of these devices, then adobe a sound "prove dead" approach to testing. Before making a test, test the driver on a known live conductor and ensure it lights up. Next test the unknown conductor, and ensure it does not light, Finally test again on a known life conductor.

Legality

There is some question as to whether these tools, are legal to use in the workplace, since they don't possess a number of the attributes deemed necessary in electrical test gear by the health and safety executive. See the document GS38 Electrical Test Equipment for Electricians (PDF) - in particular section 9.


Further discussion

uk.d-i-y thread

Alternatives

A much better alternative is a non contact volt stick:

VoltStick-2.jpg

These can give a clear and unambiguous indication of a live circuit, without even needing to open any insulating cover or make physical contact with the circuit.

Other alternatives a multimeter or other specialist electricians voltage meter. A reasonable quality meter will do far more than a neon screwdriver, and do so with more reliable results. Multimeters have their own safety issues, but they are less and much more under the control of the end user, so can be minimised with care.

See Also