- 20:02, 8 August 2007 diff hist +1 m Dimmers & Switchbanks →40w Filament Bulb: typo
- 20:01, 8 August 2007 diff hist +25 Dimmers & Switchbanks →Summary: unknitted the language a little
- 18:22, 8 August 2007 diff hist -17,541 m Talk:Main Page/Discussion A new record, 5 spammers in a day?
- 11:55, 7 August 2007 diff hist +295 Talk:Main Page/Discussion →Spam Overflow
- 11:48, 7 August 2007 diff hist -165 m Talk:Main Page/Discussion Reverted edits by 75.21.64.61 (Talk); changed back to last version by NT
- 03:34, 7 August 2007 diff hist +304 Talk:Main Page/Discussion →Spam Overflow
- 03:15, 7 August 2007 diff hist -1,771 m Talk:Main Page/Discussion rv spam
- 02:19, 6 August 2007 diff hist -3,335 m Talk:Main Page/Discussion rv spam
- 19:16, 5 August 2007 diff hist -2,377 m Talk:Main Page/Discussion rv spam
- 13:04, 4 August 2007 diff hist -957 m Talk:Main Page/Discussion Blat three spammers in one hit - result!
- 12:15, 30 July 2007 diff hist +517 RCD →Enclosure design: Added note re NVR function on some RCDs
- 11:45, 28 July 2007 diff hist -62 Electrical Circuit Faults →Causes: reword
- 11:37, 28 July 2007 diff hist -290 m TT Earthing took under construction header off since no one seemed to have anything to say on it!
- 05:38, 23 July 2007 diff hist +1 m Halogen Lighting →Low Voltage or Mains Halogen: typo
- 00:20, 22 July 2007 diff hist +141 Talk:Main Page/Discussion
- 00:18, 22 July 2007 diff hist -17,452 Motorised Valves de spam
- 00:16, 22 July 2007 diff hist -10,029 m Domestic Hot Water Systems de spam
- 00:14, 22 July 2007 diff hist -17,456 m Talk:Central heating design de spam
- 12:58, 20 July 2007 diff hist -1,243 m Talk:Main Page/Discussion revert spam
- 12:27, 18 July 2007 diff hist +376 Talk:Main Page/Discussion →blocking netblocks
- 19:24, 17 July 2007 diff hist +423 Talk:Main Page/Discussion
- 22:01, 16 July 2007 diff hist 0 m Cable crimping →Acceptable jointing methods: Add BS7671 ref in the correct place this time!
- 21:59, 16 July 2007 diff hist +37 m Cable crimping →Acceptable jointing methods: Add BS7671 ref
- 20:17, 16 July 2007 diff hist +201 Talk:Main Page/Discussion I would suggest
- 01:53, 16 July 2007 diff hist +689 Talk:Main Page/Discussion spam
- 03:07, 8 July 2007 diff hist -7,668 m Insulation rv spam
- 01:56, 5 July 2007 diff hist -547 m Talk:Main Page/Discussion rv spam
- 03:20, 4 July 2007 diff hist +211 N Talk:Stud wall
- 19:32, 3 July 2007 diff hist +310 Talk:Categories
- 19:24, 3 July 2007 diff hist +11 m Impact driver →The good: Emphases particular suitability for wood screews
- 18:54, 3 July 2007 diff hist +121 Impact driver →Jobs they are poor at: Expanded the limitations on drilling tasks section.
- 16:46, 3 July 2007 diff hist +258 Impact driver →Is a impact driver a suitable replacement to a drill driver or combi drill?: Added more info on drilling.
- 00:46, 3 July 2007 diff hist +249 Talk:Cement mixing
- 00:50, 2 July 2007 diff hist +1,209 N Dead man prop
- 00:28, 2 July 2007 diff hist +44 N File:DeadManPB.jpg Dead man prop for plasterboarding a ceiling. current
- 00:27, 2 July 2007 diff hist -820 m Talk:Main Page/Discussion rv spam
- 01:37, 1 July 2007 diff hist +668 Talk:Fluorescent Lighting Vadalism?
- 01:30, 1 July 2007 diff hist +27,891 Fluorescent Lighting rv apparent vandalism or accidental deletion of page by previous editor
- 03:29, 29 June 2007 diff hist +474 Electrical Links more info wrt to some of the links
- 22:57, 23 June 2007 diff hist +14 m Talk:Main Page/Discussion another spam bites the dust
- 19:39, 22 June 2007 diff hist +19 m Talk:Main Page/Discussion yawn
- 02:49, 22 June 2007 diff hist +52 m Talk:Main Page/Discussion Time to wave goodbye to another IP address mr spammer
- 02:03, 16 June 2007 diff hist +910 N Talk:Ufer Earthing
- 01:54, 16 June 2007 diff hist +315 Talk:Immersion Heaters Flexible Cable
- 01:03, 15 June 2007 diff hist +8,073 m Talk:Main Page/Discussion 'nother spammer
- 23:39, 13 June 2007 diff hist +1 Taking electricity outside →Using an independent supply: typo
- 23:35, 13 June 2007 diff hist +69 Earthing Types →Earthing Types: Add TT Earth link
- 07:29, 13 June 2007 diff hist 0 Taking electricity outside →CPC sizing: fix error introduced by typo in previous calc.
- 07:28, 13 June 2007 diff hist +47 Taking electricity outside →TN-S & TN-C-S Earthing at the head end: added missing assumption from calcs, corrected typo
- 23:52, 12 June 2007 diff hist +124 Taking electricity outside Added TT Earthing links
- 23:44, 12 June 2007 diff hist +636 Taking electricity outside →Using an independent supply: added warning re: Pre WW2 metal clad main fuses.
- 10:58, 12 June 2007 diff hist +5 TT Earthing →Testing the electrode resistance: broken link
- 01:52, 12 June 2007 diff hist -280 Taking electricity outside Took off work in progress header
- 01:47, 12 June 2007 diff hist +9,507 N TT Earthing Draft, ready for review
- 14:44, 9 June 2007 diff hist +240 Taking electricity outside Added surface clipped to submain routing options
- 04:25, 8 June 2007 diff hist +618 m Talk:Main Page/Discussion bye bye spammer
- 22:45, 7 June 2007 diff hist +391 Talk:Taking electricity outside
- 14:28, 7 June 2007 diff hist -174 m Electrical Circuit Faults Took off work in progress header
- 13:10, 7 June 2007 diff hist +372 Taking electricity outside Readability tweaks
- 10:23, 7 June 2007 diff hist +301 Talk:Drill bit Multi material bits
- 10:17, 7 June 2007 diff hist +701 Talk:Taking electricity outside
- 00:23, 6 June 2007 diff hist -3 m Taking electricity outside →Design: link
- 23:56, 5 June 2007 diff hist +45 m Taking electricity outside →Using an independent supply: Comment on piccie
- 23:54, 5 June 2007 diff hist +226 Taking electricity outside →Cable types: Added piccies
- 23:51, 5 June 2007 diff hist +9 N File:SWACable.jpg SWA cable current
- 23:50, 5 June 2007 diff hist +11 N File:HiTuf.jpg HiTuf cable current
- 23:49, 5 June 2007 diff hist +20 N File:FlatT&E.jpg Twin and Earth cable current
- 23:32, 5 June 2007 diff hist +225 m Cables Replaced voltage drop title - deleted by accident
- 23:30, 5 June 2007 diff hist -1 m Cables →SWA Cable: Lose the [ I deleted from the other copy
- 16:36, 5 June 2007 diff hist +830 Power Tools Added links to FAQ pages when we have entries for the tools
- 11:25, 5 June 2007 diff hist 0 Taking electricity outside →CPC sizing: Brain fart in equation
- 23:58, 4 June 2007 diff hist -2 m Taking electricity outside →From an existing circuit: broken link
- 21:49, 4 June 2007 diff hist +1,157 Taking electricity outside First draft - ready for review
- 21:37, 4 June 2007 diff hist +35 N File:MainCutoutandMeter.jpg Main cutout fuse and electric meter current
- 21:19, 4 June 2007 diff hist +79 N File:RCDSwitchFuse.jpg Switchfuse setup in a DIN enclosure with time delayed MCB and HRC fuse carrier. current
- 21:13, 4 June 2007 diff hist +77 N File:MainSwitchandHenley.jpg Picture showing a main switch and service connector block in the meter tails.
- 18:58, 4 June 2007 diff hist +4,946 Taking electricity outside Most stuff in place. Needs proof reading etc.
- 18:18, 4 June 2007 diff hist +1 Taking electricity outside →CPC sizing
- 03:34, 4 June 2007 diff hist +102 Talk:Cables Woa there! NT
- 03:32, 4 June 2007 diff hist +10,703 Taking electricity outside More done, still not proof read, and outbuilding stuff and testing to do.
- 06:41, 3 June 2007 diff hist +17,277 N Taking electricity outside work in progress
- 12:29, 2 June 2007 diff hist +649 N Talk:Twisted Flex Joints
- 20:59, 1 June 2007 diff hist +19 m Plumbing →Copper: missing words
- 11:55, 1 June 2007 diff hist +355 m Talk:Main Page/Discussion rv spam
- 18:12, 30 May 2007 diff hist -337 m Talk:Main Page/Discussion Revert contribution from spamming retard
- 15:33, 30 May 2007 diff hist +516 Talk:House Wiring for Beginners
- 12:47, 30 May 2007 diff hist +1,094 Talk:House Wiring for Beginners
- 10:34, 30 May 2007 diff hist +785 m Talk:Main Page/Discussion Despamify
- 02:05, 30 May 2007 diff hist -6 m House Wiring for Beginners →Showers: fixed link
- 02:05, 30 May 2007 diff hist -6 m House Wiring for Beginners →Zones: fixed link
- 02:04, 30 May 2007 diff hist +101 House Wiring for Beginners →Sockets: Changed advice on sockets - explicitly forbidded by [601-08-01]
- 01:53, 30 May 2007 diff hist +259 House Wiring for Beginners →Zones: Added IP ratings wrt zones for accessories
- 02:42, 29 May 2007 diff hist 0 m RCD →Wiring faults: missing )
- 02:36, 29 May 2007 diff hist -2 m RCD →ELCB: Typo, plus rccb at wrong heading level
- 02:26, 29 May 2007 diff hist -6 m RCD →RCD: grammar
- 19:23, 28 May 2007 diff hist +452 Talk:Main Page/Discussion Reformat glossary pages?
- 19:18, 28 May 2007 diff hist +174 Talk:Main Page/Discussion
- 19:11, 28 May 2007 diff hist +922 Talk:RCD
- 02:13, 28 May 2007 diff hist +631 Talk:RCD
- 21:54, 27 May 2007 diff hist -1 RCD →Mitigating the effects of nuisance trips: Auto numbering was broken, changed to bullets